Adaptation of the Griess Reaction for Detection of Nitrite in Human Plasma
Daniela Giustarini, Isabella Dalle‐Donne, Roberto Colombo, Aldo Milzani, Ranieri Rossi
Abstract
Daniela Giustarini, Isabella Dalle‐Donne, Roberto Colombo, Aldo Milzani, Ranieri Rossi
Abstract
The determination of nitrite in human plasma or serum has been most frequently used as a marker of nitric oxide (NO) production. In addition, it has recently been suggested that nitrite could act as a vasodilating agent at physiological concentrations by NO delivery. Therefore, nitrite determination in biological fluids is becoming increasingly important. The most frequently used method to measure nitrite is based on the spectrophotometric analysis of the azo dye obtained after reaction with the Griess reagent. This method has some limitations regarding detection limit and sensitivity, thus resulting unsuitable for nitrite detection in plasma. We have identified some drawbacks and modified the original procedure to overcome these problems. By the use of the newly developed method, we measured 221+/-72 nM nitrite in human plasma from healthy donors.
OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The determination of nitrite in human plasma or serum has been most frequently used as a marker of nitric oxide (NO) production. In addition, it has recently been suggested that nitrite could act as a vasodilating agent at physiological concentrations by NO delivery. Therefore, nitrite determination in biological fluids is becoming increasingly important. The most frequently used method to measure nitrite is based on the spectrophotometric analysis of the azo dye obtained after reaction with the Griess reagent. This method has some limitations regarding detection limit and sensitivity, thus resulting unsuitable for nitrite detection in plasma. We have identified some drawbacks and modified the original procedure to overcome these problems. By the use of the newly developed method, we measured 221+/-72 nM nitrite in human plasma from healthy donors.
Key concepts: Nitrite, Griess test, Nitric oxide, Detection limit, Chemistry, Human plasma, Reagent, Biological fluids