2010•Journal of Medical VirologyRequires access

Long‐term serological follow‐up of blood donors with an HTLV‐Indeterminate Western Blot: Antibody Profile of Seroconverters and Individuals With False Reactions

Marina Lobato Martins, Ana Carolina da Silva Santos, Maria Sueli Silva Namen-Lopes, Edel Figueiredo Barbosa‐Stancioli, Denise Utsch Gonçalves, Anna Barbara F. Carneiro‐Proietti

Open publisher page 29 citations

Abstract

The high proportion of indeterminate results of the screening test for human T-lymphotropic virus (HTLV) infection has been a challenge worldwide. In this study, 60 persons with seroindeterminate results for HTLV were followed until their serological status was defined. At least two independent serological tests (EIA and WB) from sequential samples were performed at an average interval of 4.4 years, totaling 141 serum samples tested. Seroconversion occurred in 12 individuals (reactive by EIA, positive by WB and PCR), and 48 were classified as false reactions (non-reactive EIA and negative PCR, but indeterminate WB). The seroconverter group had epidemiological features similar to those seen in HTLV-1 carriers, and the average time of follow-up for seroconversion was 4 years. In the group with false reactions, the most frequent indeterminate WB pattern in the samples was the presence of p24 alone. This pattern was absent in the seroconverter group, suggesting that p24 alone is an indicator of false reactivity. In contrast, the presence of p19 and p24 seems to be an indicator of true reactivity, since this pattern was frequent (66.7%) among the seroconverters and much less common (10.4% of the first samples) among the individuals with false reactions (P = 0.0001). Thus, HTLV infection may be suspected when reactivity to p19 and p24 is observed. Individuals with an indeterminate WB pattern should be followed-up and retested. The improvement of the HTLV algorithm screening of blood donors has been necessary to reduce inconclusive results and to avoid unnecessary follow-up to define the status of infection.

About this research paper

What this paper is about

The high proportion of indeterminate results of the screening test for human T-lymphotropic virus (HTLV) infection has been a challenge worldwide. In this study, 60 persons with seroindeterminate results for HTLV were followed until their serological status was defined. At least two independent serological tests (EIA and WB) from sequential samples were performed at an average interval of 4.4 years, totaling 141 serum samples tested. Seroconversion occurred in 12 individuals (reactive by EIA, positive by WB and PCR), and 48 were classified as false reactions (non-reactive EIA and negative PCR, but indeterminate WB). The seroconverter group had epidemiological features similar to those seen in HTLV-1 carriers, and the average time of follow-up for seroconversion was 4 years. In the group with false reactions, the most frequent indeterminate WB pattern in the samples was the presence of p24 alone. This pattern was absent in the seroconverter group, suggesting that p24 alone is an indicator of false reactivity. In contrast, the presence of p19 and p24 seems to be an indicator of true reactivity, since this pattern was frequent (66.7%) among the seroconverters and much less common (10.4% of the first samples) among the individuals with false reactions (P = 0.0001). Thus, HTLV infection may be suspected when reactivity to p19 and p24 is observed. Individuals with an indeterminate WB pattern should be followed-up and retested. The improvement of the HTLV algorithm screening of blood donors has been necessary to reduce inconclusive results and to avoid unnecessary follow-up to define the status of infection.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The high proportion of indeterminate results of the screening test for human T-lymphotropic virus (HTLV) infection has been a challenge worldwide. In this study, 60 persons with seroindeterminate results for HTLV were followed until their serological status was defined. At least two independent serological tests (EIA and WB) from sequential samples were performed at an average interval of 4.4 years, totaling 141 serum samples tested. Seroconversion occurred in 12 individuals (reactive by EIA, positive by WB and PCR), and 48 were classified as false reactions (non-reactive EIA and negative PCR, but indeterminate WB). The seroconverter group had epidemiological features similar to those seen in HTLV-1 carriers, and the average time of follow-up for seroconversion was 4 years. In the group with false reactions, the most frequent indeterminate WB pattern in the samples was the presence of p24 alone. This pattern was absent in the seroconverter group, suggesting that p24 alone is an indicator of false reactivity. In contrast, the presence of p19 and p24 seems to be an indicator of true reactivity, since this pattern was frequent (66.7%) among the seroconverters and much less common (10.4% of the first samples) among the individuals with false reactions (P = 0.0001). Thus, HTLV infection may be suspected when reactivity to p19 and p24 is observed. Individuals with an indeterminate WB pattern should be followed-up and retested. The improvement of the HTLV algorithm screening of blood donors has been necessary to reduce inconclusive results and to avoid unnecessary follow-up to define the status of infection.

Key concepts: Indeterminate, Seroconversion, Serology, Medicine, Virology, Antibody, Immunology, Epidemiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Long‐term serological follow‐up of blood donors with an HTLV‐Indeterminate Western Blot: Antibody Profile of Seroconverters and Individuals With False Reactions — Research Paper | ScholarLens