2001The AnalystRequires access

Determination of ascorbyl 6-palmitate in food matrices by amperometric flow injection analysis

Susanna Buratti, Maria Stella Cosio, S. Benedetti, Saverio Mannino

Open publisher page 6 citations

Abstract

In this paper a rapid method based on a FIA (flow injection analysis) system with amperometric detection for the evaluation of ascorbyl 6-palmitate in foods is described. The selectivity of the proposed method is related to the low anodic potential applied to the working glassy carbon electrode (+0.1 V vs. Ag/AgCl) that leaves out interferences from ascorbic acid and phenolic compounds. By flow injection analysis, under optimised conditions, the calibration curve was linear in the range 0-20 mg l(-1) and the detection limit was 0.2 mg l(-1).

About this research paper

What this paper is about

In this paper a rapid method based on a FIA (flow injection analysis) system with amperometric detection for the evaluation of ascorbyl 6-palmitate in foods is described. The selectivity of the proposed method is related to the low anodic potential applied to the working glassy carbon electrode (+0.1 V vs. Ag/AgCl) that leaves out interferences from ascorbic acid and phenolic compounds. By flow injection analysis, under optimised conditions, the calibration curve was linear in the range 0-20 mg l(-1) and the detection limit was 0.2 mg l(-1).

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper a rapid method based on a FIA (flow injection analysis) system with amperometric detection for the evaluation of ascorbyl 6-palmitate in foods is described. The selectivity of the proposed method is related to the low anodic potential applied to the working glassy carbon electrode (+0.1 V vs. Ag/AgCl) that leaves out interferences from ascorbic acid and phenolic compounds. By flow injection analysis, under optimised conditions, the calibration curve was linear in the range 0-20 mg l(-1) and the detection limit was 0.2 mg l(-1).

Key concepts: Amperometry, Flow injection analysis, Ascorbic acid, Detection limit, Chemistry, Calibration curve, Linear range, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ascorbyl 6-palmitate in food matrices by amperometric flow injection analysis — Research Paper | ScholarLens