1982CirculationRequires access

Cycle length alternation in circus movement tachycardia using an atrioventricular accessory pathway. A study of the role of the atrioventricular node using a computer model of tachycardia.

David L. Ross, W.R.M. Dassen, E. J. Vanagt, P. Brugada, Frits W. Bär, H. J. J. Wellens

Open publisher page 30 citations

Abstract

The possible role of the atrioventricular nodal (AVN) function curve during tachycardia as a cause of cycle length alternation was investigated using a computer model of circus movement tachycardia utilizing an atrioventricular accessory pathway. Two types of AVN function curves during tachycardia were entered into the computer: straight lines of various gradients and representative examples of patient-based AVN function curves obtained during clinical electrophysiologic studies. Perturbations of the tachycardia model were induced by introducing a short cycle, by suddenly prolonging a conduction interval, or by moving the AVN function curve relative to that in stable tachycardia. Using the straight line AVN function curves, stable, sustained cycle length alternation could be induced by perturbation of the tachycardia cycle if the gradient of the line was -1 (slope = 45 degrees). If the gradient was more than -1 (slope less than 45 degrees), the perturbation was damped. If the gradient was less than -1 (slope greater than 45 degrees), the perturbation was amplified, leading to termination of tachycardia by block in the AVN. Similar but more complex responses to perturbation of tachycardia were found using patient-based AVN function curves. Thus, sustained cycle length alternation and amplification or damping of perturbation could be produced. Using physiologic AVN function curves, the response to perturbation of tachycardia depended on the interrelationship of the shape of the AVN function curve, the location of the cycle length of tachycardia on the curve, the magnitude and direction of the perturbation, and the AVN effective refractory period. We conclude that cycle length alternation during tachycardia may be explained by the characteristics of a single antegrade AVN function curve without postulating the presence of additional AVN pathways. The stability of circus movement tachycardias depends on the interaction of several variables.

About this research paper

What this paper is about

The possible role of the atrioventricular nodal (AVN) function curve during tachycardia as a cause of cycle length alternation was investigated using a computer model of circus movement tachycardia utilizing an atrioventricular accessory pathway. Two types of AVN function curves during tachycardia were entered into the computer: straight lines of various gradients and representative examples of patient-based AVN function curves obtained during clinical electrophysiologic studies. Perturbations of the tachycardia model were induced by introducing a short cycle, by suddenly prolonging a conduction interval, or by moving the AVN function curve relative to that in stable tachycardia. Using the straight line AVN function curves, stable, sustained cycle length alternation could be induced by perturbation of the tachycardia cycle if the gradient of the line was -1 (slope = 45 degrees). If the gradient was more than -1 (slope less than 45 degrees), the perturbation was damped. If the gradient was less than -1 (slope greater than 45 degrees), the perturbation was amplified, leading to termination of tachycardia by block in the AVN. Similar but more complex responses to perturbation of tachycardia were found using patient-based AVN function curves. Thus, sustained cycle length alternation and amplification or damping of perturbation could be produced. Using physiologic AVN function curves, the response to perturbation of tachycardia depended on the interrelationship of the shape of the AVN function curve, the location of the cycle length of tachycardia on the curve, the magnitude and direction of the perturbation, and the AVN effective refractory period. We conclude that cycle length alternation during tachycardia may be explained by the characteristics of a single antegrade AVN function curve without postulating the presence of additional AVN pathways. The stability of circus movement tachycardias depends on the interaction of several variables.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The possible role of the atrioventricular nodal (AVN) function curve during tachycardia as a cause of cycle length alternation was investigated using a computer model of circus movement tachycardia utilizing an atrioventricular accessory pathway. Two types of AVN function curves during tachycardia were entered into the computer: straight lines of various gradients and representative examples of patient-based AVN function curves obtained during clinical electrophysiologic studies. Perturbations of the tachycardia model were induced by introducing a short cycle, by suddenly prolonging a conduction interval, or by moving the AVN function curve relative to that in stable tachycardia. Using the straight line AVN function curves, stable, sustained cycle length alternation could be induced by perturbation of the tachycardia cycle if the gradient of the line was -1 (slope = 45 degrees). If the gradient was more than -1 (slope less than 45 degrees), the perturbation was damped. If the gradient was less than -1 (slope greater than 45 degrees), the perturbation was amplified, leading to termination of tachycardia by block in the AVN. Similar but more complex responses to perturbation of tachycardia were found using patient-based AVN function curves. Thus, sustained cycle length alternation and amplification or damping of perturbation could be produced. Using physiologic AVN function curves, the response to perturbation of tachycardia depended on the interrelationship of the shape of the AVN function curve, the location of the cycle length of tachycardia on the curve, the magnitude and direction of the perturbation, and the AVN effective refractory period. We conclude that cycle length alternation during tachycardia may be explained by the characteristics of a single antegrade AVN function curve without postulating the presence of additional AVN pathways. The stability of circus movement tachycardias depends on the interaction of several variables.

Key concepts: Tachycardia, Atrioventricular reentrant tachycardia, Medicine, Atrioventricular node, Internal medicine, Cardiology, Perturbation (astronomy), Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Cycle length alternation in circus movement tachycardia using an atrioventricular accessory pathway. A study of the role of the atrioventricular node using a computer model of tachycardia. — Research Paper | ScholarLens