2014Circulation JournalOpen access

Impact of Target Lesion Coronary Calcification on Stent Expansion

Yuhei Kobayashi, Hiroyuki Okura, Teruyoshi Kume, Ryotaro Yamada, Yukari Kobayashi, Kenzo Fukuhara, Terumasa Koyama, Shintaro Nezuo, Yoji Neishi, Akihiro Hayashida, Takahiro Kawamoto, Kiyoshi Yoshida

Open full text 260 citations

Abstract

BACKGROUND: Stent underexpansion remains a concern as a cause of drug-eluting stent (DES) failure. Although coronary calcification is considered to be a contributing factor in stent underexpansion, previous intravascular ultrasound studies have failed to demonstrate this relationship. We investigated whether stent expansion could be predicted by coronary calcification as assessed by optical coherence tomography (OCT). METHODS AND RESULTS: We enrolled 51 de novo native coronary artery lesions treated by a single 2nd-generation DES (3 types). Prior to stent deployment, the arc and area of calcium at the target lesion were measured using OCT. After successful stent implantation, OCT imaging was repeated to assess minimal stent diameter and area (MSD and MSA). Stent expansion was defined as MSD (or MSA) divided by the values predicted by the manufacturers' compliance charts. Patients were divided into 4 groups according to the median values of the arc and area of calcium. Mean stent expansion was 73.3±8.7% for MSD and 65.2±12.0% for MSA. Stent expansion defined by MSD was significantly different among the 4 groups (P=0.02). A similar trend was observed for stent expansion defined by MSA (P=0.16). CONCLUSIONS: The extent of target lesion calcification as assessed by OCT may be an important determinant of the expansion of 2nd-generation DES.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Stent underexpansion remains a concern as a cause of drug-eluting stent (DES) failure. Although coronary calcification is considered to be a contributing factor in stent underexpansion, previous intravascular ultrasound studies have failed to demonstrate this relationship. We investigated whether stent expansion could be predicted by coronary calcification as assessed by optical coherence tomography (OCT). METHODS AND RESULTS: We enrolled 51 de novo native coronary artery lesions treated by a single 2nd-generation DES (3 types). Prior to stent deployment, the arc and area of calcium at the target lesion were measured using OCT. After successful stent implantation, OCT imaging was repeated to assess minimal stent diameter and area (MSD and MSA). Stent expansion was defined as MSD (or MSA) divided by the values predicted by the manufacturers' compliance charts. Patients were divided into 4 groups according to the median values of the arc and area of calcium. Mean stent expansion was 73.3±8.7% for MSD and 65.2±12.0% for MSA. Stent expansion defined by MSD was significantly different among the 4 groups (P=0.02). A similar trend was observed for stent expansion defined by MSA (P=0.16). CONCLUSIONS: The extent of target lesion calcification as assessed by OCT may be an important determinant of the expansion of 2nd-generation DES.

Why it matters

OpenAlex reports 260 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Stent underexpansion remains a concern as a cause of drug-eluting stent (DES) failure. Although coronary calcification is considered to be a contributing factor in stent underexpansion, previous intravascular ultrasound studies have failed to demonstrate this relationship. We investigated whether stent expansion could be predicted by coronary calcification as assessed by optical coherence tomography (OCT). METHODS AND RESULTS: We enrolled 51 de novo native coronary artery lesions treated by a single 2nd-generation DES (3 types). Prior to stent deployment, the arc and area of calcium at the target lesion were measured using OCT. After successful stent implantation, OCT imaging was repeated to assess minimal stent diameter and area (MSD and MSA). Stent expansion was defined as MSD (or MSA) divided by the values predicted by the manufacturers' compliance charts. Patients were divided into 4 groups according to the median values of the arc and area of calcium. Mean stent expansion was 73.3±8.7% for MSD and 65.2±12.0% for MSA. Stent expansion defined by MSD was significantly different among the 4 groups (P=0.02). A similar trend was observed for stent expansion defined by MSA (P=0.16). CONCLUSIONS: The extent of target lesion calcification as assessed by OCT may be an important determinant of the expansion of 2nd-generation DES.

Key concepts: Stent, Calcification, Intravascular ultrasound, Medicine, Optical coherence tomography, Restenosis, Lesion, Target lesion

Related papers

Back to paper searchBrowse research topicsOriginal source
Impact of Target Lesion Coronary Calcification on Stent Expansion — Research Paper | ScholarLens