Is neonatal inspired gas humidity accurately controlled by humidifier temperature?

Malachy O'Hagan, Elizabeth Reid, William Odita Tarnow-Mordi

Open publisher page 22 citations

Abstract

OBJECTIVE: To investigate: a) the relationship between humidifier temperature and inspired gas humidity and b) the effect of insulating the inspiratory tube on "rainout" (condensate). DESIGN: Observational study. SETTING: Regional neonatal unit in a university hospital. PATIENTS: Forty-eight infants receiving assisted ventilation, of whom 31 infants were nursed in incubators and 17 under radiant heaters. MEASUREMENTS AND MAIN RESULTS: Despite always maintaining humidifier temperature greater than 34.7 degrees C, inspired gas humidity decreased below the American National Standards Institution minimum of 30 mg H2O/L on 35 of 479 occasions. At a humidifier temperature of 36 degrees C, inspired gas humidity varied between 17 and 43 mg H2O/L. In incubators set at a temperature of 34.1 +/- 1.3 (SD) degrees C, inspired gas humidity was linearly related to humidifier temperature, but with wide scatter (p less than .001, r2 = .28). In cooler incubators set at 32.9 +/- 1.8 degrees C, inspired gas humidity varied inversely with humidifier temperature. This variation was attributed to condensate due to inspired gas cooling within the incubator. Insulation of the inspiratory tubing reduced condensate by only 15%. CONCLUSIONS: Inspired gas humidity cannot be predicted reliably from humidifier temperature. Accurate control will require a new generation of humidifiers that measure inspired gas humidity.

About this research paper

What this paper is about

OBJECTIVE: To investigate: a) the relationship between humidifier temperature and inspired gas humidity and b) the effect of insulating the inspiratory tube on "rainout" (condensate). DESIGN: Observational study. SETTING: Regional neonatal unit in a university hospital. PATIENTS: Forty-eight infants receiving assisted ventilation, of whom 31 infants were nursed in incubators and 17 under radiant heaters. MEASUREMENTS AND MAIN RESULTS: Despite always maintaining humidifier temperature greater than 34.7 degrees C, inspired gas humidity decreased below the American National Standards Institution minimum of 30 mg H2O/L on 35 of 479 occasions. At a humidifier temperature of 36 degrees C, inspired gas humidity varied between 17 and 43 mg H2O/L. In incubators set at a temperature of 34.1 +/- 1.3 (SD) degrees C, inspired gas humidity was linearly related to humidifier temperature, but with wide scatter (p less than .001, r2 = .28). In cooler incubators set at 32.9 +/- 1.8 degrees C, inspired gas humidity varied inversely with humidifier temperature. This variation was attributed to condensate due to inspired gas cooling within the incubator. Insulation of the inspiratory tubing reduced condensate by only 15%. CONCLUSIONS: Inspired gas humidity cannot be predicted reliably from humidifier temperature. Accurate control will require a new generation of humidifiers that measure inspired gas humidity.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To investigate: a) the relationship between humidifier temperature and inspired gas humidity and b) the effect of insulating the inspiratory tube on "rainout" (condensate). DESIGN: Observational study. SETTING: Regional neonatal unit in a university hospital. PATIENTS: Forty-eight infants receiving assisted ventilation, of whom 31 infants were nursed in incubators and 17 under radiant heaters. MEASUREMENTS AND MAIN RESULTS: Despite always maintaining humidifier temperature greater than 34.7 degrees C, inspired gas humidity decreased below the American National Standards Institution minimum of 30 mg H2O/L on 35 of 479 occasions. At a humidifier temperature of 36 degrees C, inspired gas humidity varied between 17 and 43 mg H2O/L. In incubators set at a temperature of 34.1 +/- 1.3 (SD) degrees C, inspired gas humidity was linearly related to humidifier temperature, but with wide scatter (p less than .001, r2 = .28). In cooler incubators set at 32.9 +/- 1.8 degrees C, inspired gas humidity varied inversely with humidifier temperature. This variation was attributed to condensate due to inspired gas cooling within the incubator. Insulation of the inspiratory tubing reduced condensate by only 15%. CONCLUSIONS: Inspired gas humidity cannot be predicted reliably from humidifier temperature. Accurate control will require a new generation of humidifiers that measure inspired gas humidity.

Key concepts: Humidifiers, Humidity, Incubator, Medicine, Ventilation (architecture), Relative humidity, Environmental science, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Is neonatal inspired gas humidity accurately controlled by humidifier temperature? — Research Paper | ScholarLens