1987IEEE Transactions on Instrumentation and MeasurementRequires access

Precise capacitance measurements of high-voltage compressed gas capacitors

Hans-Georg Latzel, Klaus Schon

Open publisher page 23 citations

Abstract

The parameters affecting the capacitance measurement of compressed gas capacitors which are used as high-voltage standards are investigated. The temperature coefficient of compressed gas capacitors in the range of 2 to 3 · 10−5K−1, as well as inevitable ambient temperature changes and gradients within high-voltage halls, were found to be mainly responsible for the limitation in the accuracy of precise capacitance measurements. A method is given to distinguish between capacitors with high- and low- voltage dependence of capacitance, without applying high voltage to them. The voltage dependence of a commercially available 120-kV, 100-pF capacitor could be considerably reduced by renewing and readjusting its electrode system. The natural frequencies of the mechanical electrode system of capacitors with rated voltages between 100 and 800 kV were found to be between 38 and 8 Hz, respectively.

About this research paper

What this paper is about

The parameters affecting the capacitance measurement of compressed gas capacitors which are used as high-voltage standards are investigated. The temperature coefficient of compressed gas capacitors in the range of 2 to 3 · 10−5K−1, as well as inevitable ambient temperature changes and gradients within high-voltage halls, were found to be mainly responsible for the limitation in the accuracy of precise capacitance measurements. A method is given to distinguish between capacitors with high- and low- voltage dependence of capacitance, without applying high voltage to them. The voltage dependence of a commercially available 120-kV, 100-pF capacitor could be considerably reduced by renewing and readjusting its electrode system. The natural frequencies of the mechanical electrode system of capacitors with rated voltages between 100 and 800 kV were found to be between 38 and 8 Hz, respectively.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The parameters affecting the capacitance measurement of compressed gas capacitors which are used as high-voltage standards are investigated. The temperature coefficient of compressed gas capacitors in the range of 2 to 3 · 10−5K−1, as well as inevitable ambient temperature changes and gradients within high-voltage halls, were found to be mainly responsible for the limitation in the accuracy of precise capacitance measurements. A method is given to distinguish between capacitors with high- and low- voltage dependence of capacitance, without applying high voltage to them. The voltage dependence of a commercially available 120-kV, 100-pF capacitor could be considerably reduced by renewing and readjusting its electrode system. The natural frequencies of the mechanical electrode system of capacitors with rated voltages between 100 and 800 kV were found to be between 38 and 8 Hz, respectively.

Key concepts: Capacitor, Capacitance, Voltage, Electrical engineering, Materials science, Electrode, Analytical Chemistry (journal), High voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Precise capacitance measurements of high-voltage compressed gas capacitors — Research Paper | ScholarLens