Extractive Spectrophotometric Method for Determination of Molybdenum in Steels and Environmental Samples
Rameshwar Dass, Jitander Kumar Kapoor, Sunita Gambhir
Abstract
Open-access reader
Rameshwar Dass, Jitander Kumar Kapoor, Sunita Gambhir
Abstract
Open-access reader
An extractive spectrophotometric method has been developed for microdetermination of molybdenum. At room temperature Mo(VI) was reduced to Mo(V) in 2 M H2SO4using ascorbic acid as a reductant. The Mo(V) formed a yellow‐coloured (1 : 2) complex with 6‐chloro‐3‐hydroxy‐2‐(3′‐hydroxyphenyl)‐4‐oxo‐4H‐1‐benzopyran (CHHB). The complex was quantitatively extracted into toluene and absorbed maximum atλmax404 nm. Beer’s law was obeyed over the concentration range of 2.31 μg Mo ml−1with a molar absorptivity and Sandell′s sensitivity of 5.62 × 104 L mol−1 cm−1and 0.0016 μg Mo cm−2, respectively. The relative standard deviation was 0.0025 (in absorbance units) for 10 replicate determinations of 1 μg Mo ml−1. The method was free from the interference of large number of analytically important elements. Molybdenum has been determined satisfactorily in different technical, synthetic, and environmental samples with improved accuracy and precision.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An extractive spectrophotometric method has been developed for microdetermination of molybdenum. At room temperature Mo(VI) was reduced to Mo(V) in 2 M H2SO4using ascorbic acid as a reductant. The Mo(V) formed a yellow‐coloured (1 : 2) complex with 6‐chloro‐3‐hydroxy‐2‐(3′‐hydroxyphenyl)‐4‐oxo‐4H‐1‐benzopyran (CHHB). The complex was quantitatively extracted into toluene and absorbed maximum atλmax404 nm. Beer’s law was obeyed over the concentration range of 2.31 μg Mo ml−1with a molar absorptivity and Sandell′s sensitivity of 5.62 × 104 L mol−1 cm−1and 0.0016 μg Mo cm−2, respectively. The relative standard deviation was 0.0025 (in absorbance units) for 10 replicate determinations of 1 μg Mo ml−1. The method was free from the interference of large number of analytically important elements. Molybdenum has been determined satisfactorily in different technical, synthetic, and environmental samples with improved accuracy and precision.
Key concepts: Chemistry, Molybdenum, Absorbance, Molar absorptivity, Relative standard deviation, Toluene, Ascorbic acid, Spectrophotometry