1982•Applied OpticsRequires access

Echelle spectrographs at grazing incidence

W. Cash

Open publisher page 71 citations

Abstract

It is shown that by using the conical diffraction mount existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft x rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV has a primary mirror and an entrance slit to the spectrograph. The system has resolution of 10(4), operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The x-ray spectrograph uses objective gratings to obtain spectral resolution of 2.8 x 10(4) over any factor of 2 in wavelength. It operates to wavelengths as short as 4 A.

About this research paper

What this paper is about

It is shown that by using the conical diffraction mount existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft x rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV has a primary mirror and an entrance slit to the spectrograph. The system has resolution of 10(4), operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The x-ray spectrograph uses objective gratings to obtain spectral resolution of 2.8 x 10(4) over any factor of 2 in wavelength. It operates to wavelengths as short as 4 A.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It is shown that by using the conical diffraction mount existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft x rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV has a primary mirror and an entrance slit to the spectrograph. The system has resolution of 10(4), operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The x-ray spectrograph uses objective gratings to obtain spectral resolution of 2.8 x 10(4) over any factor of 2 in wavelength. It operates to wavelengths as short as 4 A.

Key concepts: Spectrograph, Optics, Spectral resolution, Physics, Wavelength, Resolution (logic), Diffraction, Stray light