2000Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Thermal performance and facility seeing at the upgraded 3.8-m UK Infrared Telescope (UKIRT)

T. G. Hawarden, A. J. Adamson, Timothy C. Chuter, Nicholas P. Rees, R. Massey, Charles P. Cavedoni, Eli Ettedgui-Atad

Open publisher page 2 citations

Abstract

The upgraded 3.8 m UK Infrared Telescope employs active control of the primary mirror figure and secondary mirror alignment to constrain intrinsic wavefront errors, currently to approximately 180 nm, while a fast guider controls a tip- tilt secondary to remove telescope vibrations and tracking errors. It routinely produces images with FWHM below 0.'5 at 2.2 micrometers wavelength (the K-band). The best fully-sampled image yet recorded has FWHM equals 0.'171 and is believed still to be the best ever achieved by a ground-based telescope without the use of higher-order adaptive optics.

About this research paper

What this paper is about

The upgraded 3.8 m UK Infrared Telescope employs active control of the primary mirror figure and secondary mirror alignment to constrain intrinsic wavefront errors, currently to approximately 180 nm, while a fast guider controls a tip- tilt secondary to remove telescope vibrations and tracking errors. It routinely produces images with FWHM below 0.'5 at 2.2 micrometers wavelength (the K-band). The best fully-sampled image yet recorded has FWHM equals 0.'171 and is believed still to be the best ever achieved by a ground-based telescope without the use of higher-order adaptive optics.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The upgraded 3.8 m UK Infrared Telescope employs active control of the primary mirror figure and secondary mirror alignment to constrain intrinsic wavefront errors, currently to approximately 180 nm, while a fast guider controls a tip- tilt secondary to remove telescope vibrations and tracking errors. It routinely produces images with FWHM below 0.'5 at 2.2 micrometers wavelength (the K-band). The best fully-sampled image yet recorded has FWHM equals 0.'171 and is believed still to be the best ever achieved by a ground-based telescope without the use of higher-order adaptive optics.

Key concepts: Telescope, Infrared telescope, Adaptive optics, Physics, Full width at half maximum, Primary mirror, Optics, Infrared

Related papers

Back to paper searchBrowse research topicsOriginal source
Thermal performance and facility seeing at the upgraded 3.8-m UK Infrared Telescope (UKIRT) — Research Paper | ScholarLens