2002Indian Journal of Medical MicrobiologyOpen access

EVALUATION OF AN INDIGENOUS WESTERN BLOT KIT FOR HUMAN IMMUNODEFICIENCY VIRUS

V Lakshmi, SPD Ponamgi

Open full text 5 citations

Abstract

PURPOSE: The Western Blot test is considered a gold standard test for the confirmation of an ELISA and/or rapid assay screened reactive sample in the diagnosis of HIV infection, especially in the low risk population. In this study, an indigenously developed HIV W. Blot kit (J.Mitra & Co., New Delhi, India) was compared for its performance characteristics with a widely used Western Blot kit, HIV Blot 2.2 (Genelabs, Singapore). Antigens of both HIV-1 and the indicator antigen gp36 of HIV-2 are included in the strips. METHODS: A panel of 150 clinical serum samples was used in the evaluation. All the sera were tested simultaneously by both the kits. RESULTS: The HIV W. Blot kit had high performance characteristics (100% sensitivity and 100% specificity), like the HIV Blot 2.2. The test procedure was easy to perform. There was clear delineation of the bands. CONCLUSIONS: The interpretation of the results on the HIV W. Blot was less prone to subjective errors. The test gave positive bands at even very high serum dilutions in the test kit. This fact indicates that HIV W. Blot probably has a potential application in early phases of infection, when the antibody concentrations are still very low.

Open-access reader

About this research paper

What this paper is about

PURPOSE: The Western Blot test is considered a gold standard test for the confirmation of an ELISA and/or rapid assay screened reactive sample in the diagnosis of HIV infection, especially in the low risk population. In this study, an indigenously developed HIV W. Blot kit (J.Mitra & Co., New Delhi, India) was compared for its performance characteristics with a widely used Western Blot kit, HIV Blot 2.2 (Genelabs, Singapore). Antigens of both HIV-1 and the indicator antigen gp36 of HIV-2 are included in the strips. METHODS: A panel of 150 clinical serum samples was used in the evaluation. All the sera were tested simultaneously by both the kits. RESULTS: The HIV W. Blot kit had high performance characteristics (100% sensitivity and 100% specificity), like the HIV Blot 2.2. The test procedure was easy to perform. There was clear delineation of the bands. CONCLUSIONS: The interpretation of the results on the HIV W. Blot was less prone to subjective errors. The test gave positive bands at even very high serum dilutions in the test kit. This fact indicates that HIV W. Blot probably has a potential application in early phases of infection, when the antibody concentrations are still very low.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The Western Blot test is considered a gold standard test for the confirmation of an ELISA and/or rapid assay screened reactive sample in the diagnosis of HIV infection, especially in the low risk population. In this study, an indigenously developed HIV W. Blot kit (J.Mitra & Co., New Delhi, India) was compared for its performance characteristics with a widely used Western Blot kit, HIV Blot 2.2 (Genelabs, Singapore). Antigens of both HIV-1 and the indicator antigen gp36 of HIV-2 are included in the strips. METHODS: A panel of 150 clinical serum samples was used in the evaluation. All the sera were tested simultaneously by both the kits. RESULTS: The HIV W. Blot kit had high performance characteristics (100% sensitivity and 100% specificity), like the HIV Blot 2.2. The test procedure was easy to perform. There was clear delineation of the bands. CONCLUSIONS: The interpretation of the results on the HIV W. Blot was less prone to subjective errors. The test gave positive bands at even very high serum dilutions in the test kit. This fact indicates that HIV W. Blot probably has a potential application in early phases of infection, when the antibody concentrations are still very low.

Key concepts: Western blot, Human immunodeficiency virus (HIV), Blot, Dot blot, Virology, Population, Serial dilution, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
EVALUATION OF AN INDIGENOUS WESTERN BLOT KIT FOR HUMAN IMMUNODEFICIENCY VIRUS — Research Paper | ScholarLens