1996Biomedical ChromatographyRequires access

A comparative study of HPLC and TLC separation of amino acids using Cu(II) ion

Ravi Bhushan, Imran Ali, Shalini Sharma

Open publisher page 11 citations

Abstract

Separation of amino acids using Cu(II) by RP-HPLC and impregnated TLC is reported. For HPLC the sample mixture of amino acids containing copper (II) was injected into the column while for TLC the silica gel plates were impregnated with Cu(II). The mobile phase used in HPLC was acetate buffer (0.3 M, pH 6.0)-acetonitrile (9:1, v/v), and that in TLC was acetate buffer (0.3 M, pH 6.0):acetonitrile-n-butanol (12:5:10, by vol.). The results have been compared and discussed.

About this research paper

What this paper is about

Separation of amino acids using Cu(II) by RP-HPLC and impregnated TLC is reported. For HPLC the sample mixture of amino acids containing copper (II) was injected into the column while for TLC the silica gel plates were impregnated with Cu(II). The mobile phase used in HPLC was acetate buffer (0.3 M, pH 6.0)-acetonitrile (9:1, v/v), and that in TLC was acetate buffer (0.3 M, pH 6.0):acetonitrile-n-butanol (12:5:10, by vol.). The results have been compared and discussed.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Separation of amino acids using Cu(II) by RP-HPLC and impregnated TLC is reported. For HPLC the sample mixture of amino acids containing copper (II) was injected into the column while for TLC the silica gel plates were impregnated with Cu(II). The mobile phase used in HPLC was acetate buffer (0.3 M, pH 6.0)-acetonitrile (9:1, v/v), and that in TLC was acetate buffer (0.3 M, pH 6.0):acetonitrile-n-butanol (12:5:10, by vol.). The results have been compared and discussed.

Key concepts: Chemistry, Chromatography, Acetonitrile, High-performance liquid chromatography, Silica gel, Copper, Amino acid, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparative study of HPLC and TLC separation of amino acids using Cu(II) ion — Research Paper | ScholarLens