1998Obstetrics and GynecologyOpen access

Examination of Voiding in Seated Women Using a Remote-Controlled Ultrasound Probe

Gabriel N. Schaer

Open full text 14 citations

Abstract

BACKGROUND: A remote-controlled steering arm was developed that allows the ultrasound probe to be held on the perineum under ultrasound image guidance with the woman seated on a commercially available bedside commode. TECHNIQUE: The arm's servomechanism monitors contact pressure between the scanning head and the perineum, keeping constant gentle pressure on the perineum so that the transducer follows perineal movement. EXPERIENCE: Twenty patients with urinary incontinence and ten normal volunteers were examined during two voiding episodes, one without perineal ultrasound and one with ultrasound. Ultrasound images and intrarectal pressure measurements were displayed simultaneously on a video monitor. Bladder and urethral visibility and behavior were analyzed during bladder emptying. Of the 30 women, 28 were able to void, with and without the ultrasound probe applied. Two women were not able to urinate under observation either with or without sonography. The bladder base, bladder neck, and upper two-thirds of the urethra were visible throughout voiding in the 28 women able to void. Bladder neck opening could be observed in all of the 28 women. Bladder neck descent during initiation of voiding occurred in 17 women, whereas 11 voided without bladder neck descent. CONCLUSION: The use of this device facilitates ultrasound evaluation of micturition in the physiologic sitting position and allows bladder neck behavior to be seen during bladder emptying.

About this research paper

What this paper is about

BACKGROUND: A remote-controlled steering arm was developed that allows the ultrasound probe to be held on the perineum under ultrasound image guidance with the woman seated on a commercially available bedside commode. TECHNIQUE: The arm's servomechanism monitors contact pressure between the scanning head and the perineum, keeping constant gentle pressure on the perineum so that the transducer follows perineal movement. EXPERIENCE: Twenty patients with urinary incontinence and ten normal volunteers were examined during two voiding episodes, one without perineal ultrasound and one with ultrasound. Ultrasound images and intrarectal pressure measurements were displayed simultaneously on a video monitor. Bladder and urethral visibility and behavior were analyzed during bladder emptying. Of the 30 women, 28 were able to void, with and without the ultrasound probe applied. Two women were not able to urinate under observation either with or without sonography. The bladder base, bladder neck, and upper two-thirds of the urethra were visible throughout voiding in the 28 women able to void. Bladder neck opening could be observed in all of the 28 women. Bladder neck descent during initiation of voiding occurred in 17 women, whereas 11 voided without bladder neck descent. CONCLUSION: The use of this device facilitates ultrasound evaluation of micturition in the physiologic sitting position and allows bladder neck behavior to be seen during bladder emptying.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: A remote-controlled steering arm was developed that allows the ultrasound probe to be held on the perineum under ultrasound image guidance with the woman seated on a commercially available bedside commode. TECHNIQUE: The arm's servomechanism monitors contact pressure between the scanning head and the perineum, keeping constant gentle pressure on the perineum so that the transducer follows perineal movement. EXPERIENCE: Twenty patients with urinary incontinence and ten normal volunteers were examined during two voiding episodes, one without perineal ultrasound and one with ultrasound. Ultrasound images and intrarectal pressure measurements were displayed simultaneously on a video monitor. Bladder and urethral visibility and behavior were analyzed during bladder emptying. Of the 30 women, 28 were able to void, with and without the ultrasound probe applied. Two women were not able to urinate under observation either with or without sonography. The bladder base, bladder neck, and upper two-thirds of the urethra were visible throughout voiding in the 28 women able to void. Bladder neck opening could be observed in all of the 28 women. Bladder neck descent during initiation of voiding occurred in 17 women, whereas 11 voided without bladder neck descent. CONCLUSION: The use of this device facilitates ultrasound evaluation of micturition in the physiologic sitting position and allows bladder neck behavior to be seen during bladder emptying.

Key concepts: Medicine, Perineum, Urination, Neck of urinary bladder, Ultrasound, Urinary incontinence, Urethra, Urinary bladder

Related papers

Back to paper searchBrowse research topicsOriginal source
Examination of Voiding in Seated Women Using a Remote-Controlled Ultrasound Probe — Research Paper | ScholarLens