1997Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Steady-state and time-resolved fluorometry of fluorescent pollutants and heavy metal complexes

Ute Resch‐Genger, Knut Rurack

Open publisher page 8 citations

Abstract

Time-resolved laser-induced fluorescence spectroscopy is one of the most sensitive optical methods which is well suited for on-line in situ analysis. Here, three examples for the steady- state and time-resolved fluorescence analysis of environmentally important analytes, the fluorescent monoaromatic hydrocarbons benzene, toluene, and xylene as well as non fluorescent heavy metal ions forming a fluorescent complex with a cation coordinating fluorescence probe, are presented and the potential of both methods is discussed. For BTX, various mixtures of the spectrally similar compounds B, T, and X showing different fluorescence lifetimes were studied with both methods. As an example for fluorometric metal ion analysis, the fluorescence probe BP(OH)2 (2,2'-bipyridyl- 3,3'-diol) was employed for the determination of d10 metal ions in water and the newly developed fluorescence probe APTA for the detection of Cu(II). Cation complexation of BP(OH2 yields spectrally very similar complexes which differ in their fluorescence lifetimes. Complexation of APTA to Cu(II) leads to small spectral changes and a strong increase in fluorescence quantum yield and lifetime. For the analytes studied, a comparison of the detection limits, standard deviations, and linear dynamic range of both methods clearly demonstrates the analytical potential of time-resolved fluorometry.

About this research paper

What this paper is about

Time-resolved laser-induced fluorescence spectroscopy is one of the most sensitive optical methods which is well suited for on-line in situ analysis. Here, three examples for the steady- state and time-resolved fluorescence analysis of environmentally important analytes, the fluorescent monoaromatic hydrocarbons benzene, toluene, and xylene as well as non fluorescent heavy metal ions forming a fluorescent complex with a cation coordinating fluorescence probe, are presented and the potential of both methods is discussed. For BTX, various mixtures of the spectrally similar compounds B, T, and X showing different fluorescence lifetimes were studied with both methods. As an example for fluorometric metal ion analysis, the fluorescence probe BP(OH)2 (2,2'-bipyridyl- 3,3'-diol) was employed for the determination of d10 metal ions in water and the newly developed fluorescence probe APTA for the detection of Cu(II). Cation complexation of BP(OH2 yields spectrally very similar complexes which differ in their fluorescence lifetimes. Complexation of APTA to Cu(II) leads to small spectral changes and a strong increase in fluorescence quantum yield and lifetime. For the analytes studied, a comparison of the detection limits, standard deviations, and linear dynamic range of both methods clearly demonstrates the analytical potential of time-resolved fluorometry.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Time-resolved laser-induced fluorescence spectroscopy is one of the most sensitive optical methods which is well suited for on-line in situ analysis. Here, three examples for the steady- state and time-resolved fluorescence analysis of environmentally important analytes, the fluorescent monoaromatic hydrocarbons benzene, toluene, and xylene as well as non fluorescent heavy metal ions forming a fluorescent complex with a cation coordinating fluorescence probe, are presented and the potential of both methods is discussed. For BTX, various mixtures of the spectrally similar compounds B, T, and X showing different fluorescence lifetimes were studied with both methods. As an example for fluorometric metal ion analysis, the fluorescence probe BP(OH)2 (2,2'-bipyridyl- 3,3'-diol) was employed for the determination of d10 metal ions in water and the newly developed fluorescence probe APTA for the detection of Cu(II). Cation complexation of BP(OH2 yields spectrally very similar complexes which differ in their fluorescence lifetimes. Complexation of APTA to Cu(II) leads to small spectral changes and a strong increase in fluorescence quantum yield and lifetime. For the analytes studied, a comparison of the detection limits, standard deviations, and linear dynamic range of both methods clearly demonstrates the analytical potential of time-resolved fluorometry.

Key concepts: Fluorescence, Chemistry, Time-resolved spectroscopy, Quantum yield, Metal ions in aqueous solution, Fluorescence spectroscopy, Analytical Chemistry (journal), Analyte

Related papers

Back to paper searchBrowse research topicsOriginal source
Steady-state and time-resolved fluorometry of fluorescent pollutants and heavy metal complexes — Research Paper | ScholarLens