2014•Journal of Biomedical Graphics and ComputingOpen access

Effect of iterative reconstructions in low dose computed tomography

TBS Buxi, Anurag Yadav, Kishan Singh Rawat, Samarjit Singh Ghuman

Open full text 1 citations

Abstract

Objectives: To assess the patient radiation dose profiles in routine body image acquisitions when using iterative reconstruction (IR) methods and compare them with filtered back projection technique. Material and methods: Iterative dose profiles of 986 patients – Thorax (317), Abdomen/Pelvis (540), Thorax/Abdomen/Pelvis (129) in routine clinical practice have been evaluated and effective patient dose estimated from dose length product (DLP) Values. Within the evaluated samples, distribution of CT Dose Index (CTDI) and DLP values were calculated. Results: In Thorax, average DLP delivered was 286.30 mGy.cm which corresponded to an effective patient dose of 4.008 mSv. In Abdomen/Pelvis group, average value of DLP was 495.5 mGy, estimated dose was 7.43 mSv. In trunk study group average DLP was 570.21 mGy which corresponded to an effective dose of 8.55 mSv. Conclusion: Substantial dose reduction is achieved with iterative techniques. In 986 patients scans evaluated, average dose reduction of 33.2% in Thorax, 32.455% in Abdomen/Pelvis and 49.706% in trunk examinations were estimated.

Open-access reader

About this research paper

What this paper is about

Objectives: To assess the patient radiation dose profiles in routine body image acquisitions when using iterative reconstruction (IR) methods and compare them with filtered back projection technique. Material and methods: Iterative dose profiles of 986 patients – Thorax (317), Abdomen/Pelvis (540), Thorax/Abdomen/Pelvis (129) in routine clinical practice have been evaluated and effective patient dose estimated from dose length product (DLP) Values. Within the evaluated samples, distribution of CT Dose Index (CTDI) and DLP values were calculated. Results: In Thorax, average DLP delivered was 286.30 mGy.cm which corresponded to an effective patient dose of 4.008 mSv. In Abdomen/Pelvis group, average value of DLP was 495.5 mGy, estimated dose was 7.43 mSv. In trunk study group average DLP was 570.21 mGy which corresponded to an effective dose of 8.55 mSv. Conclusion: Substantial dose reduction is achieved with iterative techniques. In 986 patients scans evaluated, average dose reduction of 33.2% in Thorax, 32.455% in Abdomen/Pelvis and 49.706% in trunk examinations were estimated.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objectives: To assess the patient radiation dose profiles in routine body image acquisitions when using iterative reconstruction (IR) methods and compare them with filtered back projection technique. Material and methods: Iterative dose profiles of 986 patients – Thorax (317), Abdomen/Pelvis (540), Thorax/Abdomen/Pelvis (129) in routine clinical practice have been evaluated and effective patient dose estimated from dose length product (DLP) Values. Within the evaluated samples, distribution of CT Dose Index (CTDI) and DLP values were calculated. Results: In Thorax, average DLP delivered was 286.30 mGy.cm which corresponded to an effective patient dose of 4.008 mSv. In Abdomen/Pelvis group, average value of DLP was 495.5 mGy, estimated dose was 7.43 mSv. In trunk study group average DLP was 570.21 mGy which corresponded to an effective dose of 8.55 mSv. Conclusion: Substantial dose reduction is achieved with iterative techniques. In 986 patients scans evaluated, average dose reduction of 33.2% in Thorax, 32.455% in Abdomen/Pelvis and 49.706% in trunk examinations were estimated.

Key concepts: Abdomen, Pelvis, Nuclear medicine, Medicine, Thorax (insect anatomy), Radiation dose, Trunk, Effective dose (radiation)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of iterative reconstructions in low dose computed tomography — Research Paper | ScholarLens