1998•Applied OpticsRequires access

Comparative experimental investigation of thermal loading in continuous-wave Cr^4+:forsterite lasers

Alphan Sennaroğlu

Open publisher page 8 citations

Abstract

Results of a detailed experimental study aimed at reducing the thermal loading effects in room-temperature continuous-wave Cr(4+):forsterite lasers are presented. By using a Nd:YAG pump laser operated at 1.06 mum, the effect of the absorption coefficient and crystal cross-sectional area on the power performance of three crystals was compared between 12 and 36 degrees C. Experiments indicated that a low differential absorption coefficient significantly reduces the pump-induced thermal effects and cavity losses that would otherwise give rise to inefficient operation and increased temperature sensitivity. In particular, a Cr(4+):forsterite crystal with an absorption coefficient of 0.57 cm(-1) yielded as much as 900 mW of output power at 1.26 mum and a crystal temperature of 15 degrees C with an incident pump power of only 7.6 W. To the author's knowledge, the demonstrated slope efficiency of 30% represents the highest continuous-wave power performance reported to date from this laser system at elevated temperatures.

About this research paper

What this paper is about

Results of a detailed experimental study aimed at reducing the thermal loading effects in room-temperature continuous-wave Cr(4+):forsterite lasers are presented. By using a Nd:YAG pump laser operated at 1.06 mum, the effect of the absorption coefficient and crystal cross-sectional area on the power performance of three crystals was compared between 12 and 36 degrees C. Experiments indicated that a low differential absorption coefficient significantly reduces the pump-induced thermal effects and cavity losses that would otherwise give rise to inefficient operation and increased temperature sensitivity. In particular, a Cr(4+):forsterite crystal with an absorption coefficient of 0.57 cm(-1) yielded as much as 900 mW of output power at 1.26 mum and a crystal temperature of 15 degrees C with an incident pump power of only 7.6 W. To the author's knowledge, the demonstrated slope efficiency of 30% represents the highest continuous-wave power performance reported to date from this laser system at elevated temperatures.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Results of a detailed experimental study aimed at reducing the thermal loading effects in room-temperature continuous-wave Cr(4+):forsterite lasers are presented. By using a Nd:YAG pump laser operated at 1.06 mum, the effect of the absorption coefficient and crystal cross-sectional area on the power performance of three crystals was compared between 12 and 36 degrees C. Experiments indicated that a low differential absorption coefficient significantly reduces the pump-induced thermal effects and cavity losses that would otherwise give rise to inefficient operation and increased temperature sensitivity. In particular, a Cr(4+):forsterite crystal with an absorption coefficient of 0.57 cm(-1) yielded as much as 900 mW of output power at 1.26 mum and a crystal temperature of 15 degrees C with an incident pump power of only 7.6 W. To the author's knowledge, the demonstrated slope efficiency of 30% represents the highest continuous-wave power performance reported to date from this laser system at elevated temperatures.

Key concepts: Forsterite, Materials science, Attenuation coefficient, Laser, Continuous wave, Slope efficiency, Optics, Crystal (programming language)

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative experimental investigation of thermal loading in continuous-wave Cr^4+:forsterite lasers — Research Paper | ScholarLens