Epinephrine Enhances Analgesia Produced by Epidural Bupivacaine during Labor
James C. Eisenach, S. C. Grice, David M. Dewan
Abstract
James C. Eisenach, S. C. Grice, David M. Dewan
Abstract
Reports on the analgesic and hemodynamic effects of epinephrine added to bupivacaine for epidural use in obstetrics are conflicting. In this study, healthy parturients received in a random manner either 10 ml of 0.25% bupivacaine (n = 50) or 10 ml of 0.25% bupivacaine with 1:300,000 epinephrine (n = 50) epidurally. Epinephrine enhanced the analgesia produced by bupivacaine: onset was hastened (5.8 +/- 0.6 vs 8.7 +/- 0.8 min, mean +/- SEM, P less than 0.05), duration prolonged (123 +/- 7.0 vs 92 +/- 5.0 min, P less than 0.05), and the number of women requiring additional local anesthetic for analgesia decreased (9 vs 18, P less than 0.05) compared to the group receiving plain bupivacaine. The incidence of hypotension did not differ between groups. Maternal heart rate increased only after injection of the epinephrine-containing solution. The authors conclude that epinephrine 1:300,000 modestly but statistically significantly improves the analgesic efficacy of epidurally administered 0.25% bupivacaine during labor.
OpenAlex reports 78 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Reports on the analgesic and hemodynamic effects of epinephrine added to bupivacaine for epidural use in obstetrics are conflicting. In this study, healthy parturients received in a random manner either 10 ml of 0.25% bupivacaine (n = 50) or 10 ml of 0.25% bupivacaine with 1:300,000 epinephrine (n = 50) epidurally. Epinephrine enhanced the analgesia produced by bupivacaine: onset was hastened (5.8 +/- 0.6 vs 8.7 +/- 0.8 min, mean +/- SEM, P less than 0.05), duration prolonged (123 +/- 7.0 vs 92 +/- 5.0 min, P less than 0.05), and the number of women requiring additional local anesthetic for analgesia decreased (9 vs 18, P less than 0.05) compared to the group receiving plain bupivacaine. The incidence of hypotension did not differ between groups. Maternal heart rate increased only after injection of the epinephrine-containing solution. The authors conclude that epinephrine 1:300,000 modestly but statistically significantly improves the analgesic efficacy of epidurally administered 0.25% bupivacaine during labor.
Key concepts: Bupivacaine, Medicine, Epinephrine, Anesthesia, Local anesthetic, Analgesic, Hemodynamics