Sentinel node detection in cervical cancer
René H.M. Verheijen
Abstract
René H.M. Verheijen
Abstract
BACKGROUND: For superficial tumors such as melanoma, breast, and vulvar cancer, sentinel node detection prevents unnecessary extensive lymph node dissections. Sentinel node detection has not yet proved feasible in tumors, such as cervical cancer, that drain to deep pelvic lymph nodes. TECHNIQUE: We injected technetium-99m colloidal albumin around the tumor allowing preoperative lymphscintigraphy and intraoperative gamma probe detection of sentinel nodes. For visual detection, blue dye was injected at the start of surgery. EXPERIENCE: In six of 10 eligible women who had Wertheim-Meigs operations for cervical cancer stage Ib, one or more sentinel nodes could be detected by scintigraphy. Intraoperative gamma probe detection was successful in eight of ten women, whereas visual detection found sentinel nodes in only four. They were found as far as the common iliac level. One woman had positive lymph nodes, of which one was a sentinel node. CONCLUSION: Identification of sentinel nodes using radionuclide is possible in women with cervical cancer and potentially identifies women in whom lymph node dissection can be avoided.
OpenAlex reports 137 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: For superficial tumors such as melanoma, breast, and vulvar cancer, sentinel node detection prevents unnecessary extensive lymph node dissections. Sentinel node detection has not yet proved feasible in tumors, such as cervical cancer, that drain to deep pelvic lymph nodes. TECHNIQUE: We injected technetium-99m colloidal albumin around the tumor allowing preoperative lymphscintigraphy and intraoperative gamma probe detection of sentinel nodes. For visual detection, blue dye was injected at the start of surgery. EXPERIENCE: In six of 10 eligible women who had Wertheim-Meigs operations for cervical cancer stage Ib, one or more sentinel nodes could be detected by scintigraphy. Intraoperative gamma probe detection was successful in eight of ten women, whereas visual detection found sentinel nodes in only four. They were found as far as the common iliac level. One woman had positive lymph nodes, of which one was a sentinel node. CONCLUSION: Identification of sentinel nodes using radionuclide is possible in women with cervical cancer and potentially identifies women in whom lymph node dissection can be avoided.
Key concepts: Medicine, Gamma probe, Sentinel node, Vulvar cancer, Sentinel lymph node, Cervical cancer, Lymph node, Dissection (medical)