2002•NeurosurgeryRequires access

Evaluation of Vasospasm after Subarachnoid Hemorrhage by Use of Multislice Computed Tomographic Angiography

Yasunari Otawara, Kuniaki Ogasawara, Akira Ogawa, Makoto Sasaki, Kei Takahashi

Open publisher page 76 citations

Abstract

OBJECTIVE: Multislice computed tomographic angiography (CTA) can provide clearer vascular images, even of the peripheral arteries, than conventional CTA. Multislice CTA was compared with digital subtraction angiography (DSA) for the detection of cerebral vasospasm in patients with acute aneurysmal subarachnoid hemorrhage (SAH) to analyze whether multislice CTA can replace DSA in the detection of vasospasm after SAH. METHODS: Within 72 hours after the onset of symptoms, multislice CTA and DSA were performed in 20 patients with SAH. Multislice CTA and DSA were repeated on Day 7 to assess cerebral vasospasm. Regions of interest were established in the proximal and distal segments of the anterior and middle cerebral arteries on both multislice CTA and DSA images, and the agreement between the severity of vasospasm on multislice CTA and DSA images was statistically compared. The multislice Aquilon computed tomography system (Toshiba, Inc., Tokyo, Japan) used the following parameters: 1 mm collimation and 3.5 mm per rotation table increment (pitch, 3.5). RESULTS: The degree of vasospasm as revealed by multislice CTA correlated significantly with the degree of vasospasm revealed by DSA (P < 0.0001). The agreement between the severity of vasospasm on multislice images obtained via CTA and DSA in the overall, proximal, and distal segments of the cerebral arteries was 91.6, 90.8, and 92.3%, respectively. CONCLUSION: Multislice CTA can detect angiographic vasospasm after SAH with accuracy equal to that of DSA.

About this research paper

What this paper is about

OBJECTIVE: Multislice computed tomographic angiography (CTA) can provide clearer vascular images, even of the peripheral arteries, than conventional CTA. Multislice CTA was compared with digital subtraction angiography (DSA) for the detection of cerebral vasospasm in patients with acute aneurysmal subarachnoid hemorrhage (SAH) to analyze whether multislice CTA can replace DSA in the detection of vasospasm after SAH. METHODS: Within 72 hours after the onset of symptoms, multislice CTA and DSA were performed in 20 patients with SAH. Multislice CTA and DSA were repeated on Day 7 to assess cerebral vasospasm. Regions of interest were established in the proximal and distal segments of the anterior and middle cerebral arteries on both multislice CTA and DSA images, and the agreement between the severity of vasospasm on multislice CTA and DSA images was statistically compared. The multislice Aquilon computed tomography system (Toshiba, Inc., Tokyo, Japan) used the following parameters: 1 mm collimation and 3.5 mm per rotation table increment (pitch, 3.5). RESULTS: The degree of vasospasm as revealed by multislice CTA correlated significantly with the degree of vasospasm revealed by DSA (P < 0.0001). The agreement between the severity of vasospasm on multislice images obtained via CTA and DSA in the overall, proximal, and distal segments of the cerebral arteries was 91.6, 90.8, and 92.3%, respectively. CONCLUSION: Multislice CTA can detect angiographic vasospasm after SAH with accuracy equal to that of DSA.

Why it matters

OpenAlex reports 76 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Multislice computed tomographic angiography (CTA) can provide clearer vascular images, even of the peripheral arteries, than conventional CTA. Multislice CTA was compared with digital subtraction angiography (DSA) for the detection of cerebral vasospasm in patients with acute aneurysmal subarachnoid hemorrhage (SAH) to analyze whether multislice CTA can replace DSA in the detection of vasospasm after SAH. METHODS: Within 72 hours after the onset of symptoms, multislice CTA and DSA were performed in 20 patients with SAH. Multislice CTA and DSA were repeated on Day 7 to assess cerebral vasospasm. Regions of interest were established in the proximal and distal segments of the anterior and middle cerebral arteries on both multislice CTA and DSA images, and the agreement between the severity of vasospasm on multislice CTA and DSA images was statistically compared. The multislice Aquilon computed tomography system (Toshiba, Inc., Tokyo, Japan) used the following parameters: 1 mm collimation and 3.5 mm per rotation table increment (pitch, 3.5). RESULTS: The degree of vasospasm as revealed by multislice CTA correlated significantly with the degree of vasospasm revealed by DSA (P < 0.0001). The agreement between the severity of vasospasm on multislice images obtained via CTA and DSA in the overall, proximal, and distal segments of the cerebral arteries was 91.6, 90.8, and 92.3%, respectively. CONCLUSION: Multislice CTA can detect angiographic vasospasm after SAH with accuracy equal to that of DSA.

Key concepts: Medicine, Multislice, Vasospasm, Subarachnoid hemorrhage, Radiology, Digital subtraction angiography, Angiography, Multislice computed tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Vasospasm after Subarachnoid Hemorrhage by Use of Multislice Computed Tomographic Angiography — Research Paper | ScholarLens