2014Unpublished venueRequires access

Research on icing flashover characteristic of different shed type composite insulators

Tao Xu, Nan Jing, Xiaodong Wan

Open publisher page 2 citations

Abstract

With the global climate change, icing has become a common problem to China power system. Flashover problems caused by icing insulators have a serious threat to the safe operation of transmission and substations. It may result in tripping accidents, causing huge economic losses. In this paper, the artificial simulation icing flashover tests of ultra high voltage composite insulator with different shed structures (ordinary shed and anti-icing shed) have carried out in the environmental climate chamber of National Engineering Laboratory. A certain power frequency voltage applied on insulator string sample between the whole icing process, the environment temperature in the test chamber is -10 °C, the conductivity of water which used to icing is 100 μ S / cm, the temperature of water is 4 °C, the thickness of ice coating is about 13-15mm. The test result shows that the flashover voltage values are not same with different insulator shed. When equivalent salt deposit density pESDDis 0.08mg/cm2, the flashover voltage gradient of composite insulator with ordinary shed is 54.4kV/m, but the flashover voltage gradient of anti-icing type insulator is 61.0-69.4kV/m, which increased about 12%-27% than the ordinary shed type, and the increasing amplitude of flashover voltage is proportional to the number of anti-icing shed. According to test phenomenon, we can find obviously that anti-icing shed of insulator is very useful to prevent ice bridged. Based on the analysis of the test results, this paper give the reasonable external configuration of ultra high voltage transmission lines to prevent icing flashover which is very important to improve the reliability of UHV transmission project in ice covered condition.

About this research paper

What this paper is about

With the global climate change, icing has become a common problem to China power system. Flashover problems caused by icing insulators have a serious threat to the safe operation of transmission and substations. It may result in tripping accidents, causing huge economic losses. In this paper, the artificial simulation icing flashover tests of ultra high voltage composite insulator with different shed structures (ordinary shed and anti-icing shed) have carried out in the environmental climate chamber of National Engineering Laboratory. A certain power frequency voltage applied on insulator string sample between the whole icing process, the environment temperature in the test chamber is -10 °C, the conductivity of water which used to icing is 100 μ S / cm, the temperature of water is 4 °C, the thickness of ice coating is about 13-15mm. The test result shows that the flashover voltage values are not same with different insulator shed. When equivalent salt deposit density pESDDis 0.08mg/cm2, the flashover voltage gradient of composite insulator with ordinary shed is 54.4kV/m, but the flashover voltage gradient of anti-icing type insulator is 61.0-69.4kV/m, which increased about 12%-27% than the ordinary shed type, and the increasing amplitude of flashover voltage is proportional to the number of anti-icing shed. According to test phenomenon, we can find obviously that anti-icing shed of insulator is very useful to prevent ice bridged. Based on the analysis of the test results, this paper give the reasonable external configuration of ultra high voltage transmission lines to prevent icing flashover which is very important to improve the reliability of UHV transmission project in ice covered condition.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With the global climate change, icing has become a common problem to China power system. Flashover problems caused by icing insulators have a serious threat to the safe operation of transmission and substations. It may result in tripping accidents, causing huge economic losses. In this paper, the artificial simulation icing flashover tests of ultra high voltage composite insulator with different shed structures (ordinary shed and anti-icing shed) have carried out in the environmental climate chamber of National Engineering Laboratory. A certain power frequency voltage applied on insulator string sample between the whole icing process, the environment temperature in the test chamber is -10 °C, the conductivity of water which used to icing is 100 μ S / cm, the temperature of water is 4 °C, the thickness of ice coating is about 13-15mm. The test result shows that the flashover voltage values are not same with different insulator shed. When equivalent salt deposit density pESDDis 0.08mg/cm2, the flashover voltage gradient of composite insulator with ordinary shed is 54.4kV/m, but the flashover voltage gradient of anti-icing type insulator is 61.0-69.4kV/m, which increased about 12%-27% than the ordinary shed type, and the increasing amplitude of flashover voltage is proportional to the number of anti-icing shed. According to test phenomenon, we can find obviously that anti-icing shed of insulator is very useful to prevent ice bridged. Based on the analysis of the test results, this paper give the reasonable external configuration of ultra high voltage transmission lines to prevent icing flashover which is very important to improve the reliability of UHV transmission project in ice covered condition.

Key concepts: Icing, Arc flash, Insulator (electricity), Voltage, Electrical engineering, Tripping, Engineering, Materials science