1995Journal of Histochemistry & CytochemistryOpen access

Elimination of autofluorescence in immunofluorescence microscopy with digital image processing.

Chris H.A. van de Lest, Elly M. M. Versteeg, J.H. Veerkamp, Toin H. Van Kuppevelt

Open full text 79 citations

Abstract

Autofluorescence can be a very disturbing factor in immunofluorescence microscopy. We present here a method to eliminate autofluorescence. The method is based on the fact that most autofluorescent compounds have broad-banded excitation and emission spectra, whereas specific fluorescent probes have narrow spectra. Two images are recorded and digitized, one at a wavelength exciting both the fluorescent probe and the autofluorescent molecules, and one at a wavelength exciting only the latter. Subtraction of the autofluorescence signal from the total fluorescence signal, using a self-developed computer program, results in an autofluorescence-free image. The procedure is demonstrated for elimination of elastin-derived autofluorescence in human lung alveoli and for elimination of lipofuscin-derived autofluorescence in human heart muscle. The autofluorescence signal is positively correlated with tissue section thickness (r = 0.93; p < 0.0001), and can be used to correct the specific fluorescence signals for section thickness.

Open-access reader

About this research paper

What this paper is about

Autofluorescence can be a very disturbing factor in immunofluorescence microscopy. We present here a method to eliminate autofluorescence. The method is based on the fact that most autofluorescent compounds have broad-banded excitation and emission spectra, whereas specific fluorescent probes have narrow spectra. Two images are recorded and digitized, one at a wavelength exciting both the fluorescent probe and the autofluorescent molecules, and one at a wavelength exciting only the latter. Subtraction of the autofluorescence signal from the total fluorescence signal, using a self-developed computer program, results in an autofluorescence-free image. The procedure is demonstrated for elimination of elastin-derived autofluorescence in human lung alveoli and for elimination of lipofuscin-derived autofluorescence in human heart muscle. The autofluorescence signal is positively correlated with tissue section thickness (r = 0.93; p < 0.0001), and can be used to correct the specific fluorescence signals for section thickness.

Why it matters

OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Autofluorescence can be a very disturbing factor in immunofluorescence microscopy. We present here a method to eliminate autofluorescence. The method is based on the fact that most autofluorescent compounds have broad-banded excitation and emission spectra, whereas specific fluorescent probes have narrow spectra. Two images are recorded and digitized, one at a wavelength exciting both the fluorescent probe and the autofluorescent molecules, and one at a wavelength exciting only the latter. Subtraction of the autofluorescence signal from the total fluorescence signal, using a self-developed computer program, results in an autofluorescence-free image. The procedure is demonstrated for elimination of elastin-derived autofluorescence in human lung alveoli and for elimination of lipofuscin-derived autofluorescence in human heart muscle. The autofluorescence signal is positively correlated with tissue section thickness (r = 0.93; p < 0.0001), and can be used to correct the specific fluorescence signals for section thickness.

Key concepts: Autofluorescence, Fluorescence, Immunofluorescence, Microscopy, Elastin, Excitation wavelength, Fluorescence microscope, Lipofuscin

Related papers

Back to paper searchBrowse research topicsOriginal source
Elimination of autofluorescence in immunofluorescence microscopy with digital image processing. — Research Paper | ScholarLens