2006Chemical Research in ToxicologyRequires access

Quantification of Aflatoxin-B1-N7-Guanine in Human Urine by High-Performance Liquid Chromatography and Isotope Dilution Tandem Mass Spectrometry1

Patricia A. Egner, John D. Groopman, Jia-Sheng Wang, Thomas W. Kensler, Marlin D. Friesen

Open publisher page 100 citations

Abstract

We report validation of the first isotope dilution mass spectrometry method for determination of aflatoxin B(1)-N(7)-guanine (AFB(1)-N(7)-Gua), a major human aflatoxin-DNA adduct that is excreted in the urine. Measurement of urinary AFB(1)-N(7)-Gua, a biomarker of the biologically effective dose following dietary aflatoxin B(1) (AFB(1)) exposure, has helped identify AFB(1) as a risk factor in the development of hepatocellular carcinoma, a common cancer worldwide. Triple-quadrupole mass spectrometry, coupled with the use of a stable isotope-labeled internal standard (AFB(1)-N(7)-(15)N(5)-Gua) and better solid phase extraction and immunoaffinity column chromatography, have enabled us to greatly improve accuracy, precision, specificity, and sensitivity over previously published determinations. The limit of quantitation for AFB(1)-N(7)-Gua was 0.8 pg/20 mL urine (0.07 pg/mg creatinine). The method was validated for accuracy and precision over the range of 0.8-25 pg/20 mL urine, with between-day and within-day reproducibility for analysis of six aliquots of a human urine sample containing 6.0 pg/20 mL measured at <6% coefficient of variation. AFB(1)-N(7)-Gua concentrations were measured in 20 human urine samples collected in a region with known aflatoxin exposure. The mean concentration of AFB(1)-N(7)-Gua, measured in 16/20 urine samples with levels above the method's limit of quantitation, was 2.9 pg/20 mL urine (0.28 pg/mg creatinine) with a range of <0.8-7.2 pg/20 mL urine (0.04-65 pg/mg creatinine). With improved accuracy and precision, this sensitive biomarker for recent human exposure to AFB(1) will be especially useful for measuring the efficacy of planned interventions to reduce aflatoxin-related liver cancer in AFB(1)-exposed populations.

About this research paper

What this paper is about

We report validation of the first isotope dilution mass spectrometry method for determination of aflatoxin B(1)-N(7)-guanine (AFB(1)-N(7)-Gua), a major human aflatoxin-DNA adduct that is excreted in the urine. Measurement of urinary AFB(1)-N(7)-Gua, a biomarker of the biologically effective dose following dietary aflatoxin B(1) (AFB(1)) exposure, has helped identify AFB(1) as a risk factor in the development of hepatocellular carcinoma, a common cancer worldwide. Triple-quadrupole mass spectrometry, coupled with the use of a stable isotope-labeled internal standard (AFB(1)-N(7)-(15)N(5)-Gua) and better solid phase extraction and immunoaffinity column chromatography, have enabled us to greatly improve accuracy, precision, specificity, and sensitivity over previously published determinations. The limit of quantitation for AFB(1)-N(7)-Gua was 0.8 pg/20 mL urine (0.07 pg/mg creatinine). The method was validated for accuracy and precision over the range of 0.8-25 pg/20 mL urine, with between-day and within-day reproducibility for analysis of six aliquots of a human urine sample containing 6.0 pg/20 mL measured at <6% coefficient of variation. AFB(1)-N(7)-Gua concentrations were measured in 20 human urine samples collected in a region with known aflatoxin exposure. The mean concentration of AFB(1)-N(7)-Gua, measured in 16/20 urine samples with levels above the method's limit of quantitation, was 2.9 pg/20 mL urine (0.28 pg/mg creatinine) with a range of <0.8-7.2 pg/20 mL urine (0.04-65 pg/mg creatinine). With improved accuracy and precision, this sensitive biomarker for recent human exposure to AFB(1) will be especially useful for measuring the efficacy of planned interventions to reduce aflatoxin-related liver cancer in AFB(1)-exposed populations.

Why it matters

OpenAlex reports 100 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We report validation of the first isotope dilution mass spectrometry method for determination of aflatoxin B(1)-N(7)-guanine (AFB(1)-N(7)-Gua), a major human aflatoxin-DNA adduct that is excreted in the urine. Measurement of urinary AFB(1)-N(7)-Gua, a biomarker of the biologically effective dose following dietary aflatoxin B(1) (AFB(1)) exposure, has helped identify AFB(1) as a risk factor in the development of hepatocellular carcinoma, a common cancer worldwide. Triple-quadrupole mass spectrometry, coupled with the use of a stable isotope-labeled internal standard (AFB(1)-N(7)-(15)N(5)-Gua) and better solid phase extraction and immunoaffinity column chromatography, have enabled us to greatly improve accuracy, precision, specificity, and sensitivity over previously published determinations. The limit of quantitation for AFB(1)-N(7)-Gua was 0.8 pg/20 mL urine (0.07 pg/mg creatinine). The method was validated for accuracy and precision over the range of 0.8-25 pg/20 mL urine, with between-day and within-day reproducibility for analysis of six aliquots of a human urine sample containing 6.0 pg/20 mL measured at <6% coefficient of variation. AFB(1)-N(7)-Gua concentrations were measured in 20 human urine samples collected in a region with known aflatoxin exposure. The mean concentration of AFB(1)-N(7)-Gua, measured in 16/20 urine samples with levels above the method's limit of quantitation, was 2.9 pg/20 mL urine (0.28 pg/mg creatinine) with a range of <0.8-7.2 pg/20 mL urine (0.04-65 pg/mg creatinine). With improved accuracy and precision, this sensitive biomarker for recent human exposure to AFB(1) will be especially useful for measuring the efficacy of planned interventions to reduce aflatoxin-related liver cancer in AFB(1)-exposed populations.

Key concepts: Urine, Chromatography, Chemistry, Isotope dilution, Detection limit, Aflatoxin, Coefficient of variation, Solid phase extraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantification of Aflatoxin-B1-N7-Guanine in Human Urine by High-Performance Liquid Chromatography and Isotope Dilution Tandem Mass Spectrometry1 — Research Paper | ScholarLens