1993•IEEE Transactions on Power DeliveryRequires access

On-line reactive power compensation schemes for unbalanced three phase four wire distribution feeders

San-Yi Lee, Chi‐Jui Wu

Open publisher page 67 citations

Abstract

A new reactive power compensation method is developed to reduce the negative and zero sequence components of load currents and to improve the load bus power factor of unbalanced three-phase four-wire distribution feeders. Negative and zero sequence currents may cause additional losses and damage to power systems. Load compensation at the load bus is an effective method to eliminate those undesired sequence currents. The compensation technique uses a Y-connected and a Delta -connected static reactive power compensators (SVCs) to give a different amount of reactive power compensation to each phase. The compensation formulas are very suitable for on-line control by measurement of phase voltages and currents in real time. The compensation effect can also be achieved even if one leg of the SVCs is out of service. In addition to balancing effect and power factor improvement at the load bus, the SVCs can also be used to support the load bus voltage and to maintain the substation feeder at unity power factor. Digital simulations are made with the load data measured from an 11.4 kV secondary substation feeder.>

About this research paper

What this paper is about

A new reactive power compensation method is developed to reduce the negative and zero sequence components of load currents and to improve the load bus power factor of unbalanced three-phase four-wire distribution feeders. Negative and zero sequence currents may cause additional losses and damage to power systems. Load compensation at the load bus is an effective method to eliminate those undesired sequence currents. The compensation technique uses a Y-connected and a Delta -connected static reactive power compensators (SVCs) to give a different amount of reactive power compensation to each phase. The compensation formulas are very suitable for on-line control by measurement of phase voltages and currents in real time. The compensation effect can also be achieved even if one leg of the SVCs is out of service. In addition to balancing effect and power factor improvement at the load bus, the SVCs can also be used to support the load bus voltage and to maintain the substation feeder at unity power factor. Digital simulations are made with the load data measured from an 11.4 kV secondary substation feeder.>

Why it matters

OpenAlex reports 67 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new reactive power compensation method is developed to reduce the negative and zero sequence components of load currents and to improve the load bus power factor of unbalanced three-phase four-wire distribution feeders. Negative and zero sequence currents may cause additional losses and damage to power systems. Load compensation at the load bus is an effective method to eliminate those undesired sequence currents. The compensation technique uses a Y-connected and a Delta -connected static reactive power compensators (SVCs) to give a different amount of reactive power compensation to each phase. The compensation formulas are very suitable for on-line control by measurement of phase voltages and currents in real time. The compensation effect can also be achieved even if one leg of the SVCs is out of service. In addition to balancing effect and power factor improvement at the load bus, the SVCs can also be used to support the load bus voltage and to maintain the substation feeder at unity power factor. Digital simulations are made with the load data measured from an 11.4 kV secondary substation feeder.>

Key concepts: AC power, Power factor, Compensation (psychology), Three-phase, Power (physics), Line (geometry), Voltage, Electrical engineering