2009•The Journal of the Acoustical Society of AmericaRequires access

Closed-loop adaptive feedback control of cavitation during high-intensity focussed ultrasound therapy.

Natalie Hockham, Manish Arora, Constantin C. Coussios

Open publisher page 1 citations

Abstract

Prior experimental evidence indicates that the occurrence of inertial cavitation at the HIFU focus enhances the local rate of heat deposition, due to increased absorption of the broadband emissions associated with collapsing bubbles. However, initiating and sustaining cavitation activity throughout HIFU exposure remain a major challenge. Previous open-loop attempts at maintaining cavitation activity by varying the HIFU pulse duration have necessitated the use of duty cycles on the order of 20%, which are too low to achieve ablative temperatures. The present work presents the design, validation, and testing of a real-time closed-loop adaptive controller for sustaining thermally relevant cavitation within the HIFU focal region at duty cycles in excess of 95%. During 1.067 MHz HIFU exposure of an agar tissue-mimicking material, cavitation activity is continuously monitored and quantified using a single-element broadband passive cavitation detector (PCD) positioned coaxially with the HIFU transducer. The HIFU amplitude is adaptively modulated in direct response to the PCD signal, making it possible to maintain cavitation activity and a temperature rise in excess of 30 °C for more than 30 s. Most importantly, the acoustic energy needed to achieve such focal heating is only a fraction of that required in the absence of cavitation control.

About this research paper

What this paper is about

Prior experimental evidence indicates that the occurrence of inertial cavitation at the HIFU focus enhances the local rate of heat deposition, due to increased absorption of the broadband emissions associated with collapsing bubbles. However, initiating and sustaining cavitation activity throughout HIFU exposure remain a major challenge. Previous open-loop attempts at maintaining cavitation activity by varying the HIFU pulse duration have necessitated the use of duty cycles on the order of 20%, which are too low to achieve ablative temperatures. The present work presents the design, validation, and testing of a real-time closed-loop adaptive controller for sustaining thermally relevant cavitation within the HIFU focal region at duty cycles in excess of 95%. During 1.067 MHz HIFU exposure of an agar tissue-mimicking material, cavitation activity is continuously monitored and quantified using a single-element broadband passive cavitation detector (PCD) positioned coaxially with the HIFU transducer. The HIFU amplitude is adaptively modulated in direct response to the PCD signal, making it possible to maintain cavitation activity and a temperature rise in excess of 30 °C for more than 30 s. Most importantly, the acoustic energy needed to achieve such focal heating is only a fraction of that required in the absence of cavitation control.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Prior experimental evidence indicates that the occurrence of inertial cavitation at the HIFU focus enhances the local rate of heat deposition, due to increased absorption of the broadband emissions associated with collapsing bubbles. However, initiating and sustaining cavitation activity throughout HIFU exposure remain a major challenge. Previous open-loop attempts at maintaining cavitation activity by varying the HIFU pulse duration have necessitated the use of duty cycles on the order of 20%, which are too low to achieve ablative temperatures. The present work presents the design, validation, and testing of a real-time closed-loop adaptive controller for sustaining thermally relevant cavitation within the HIFU focal region at duty cycles in excess of 95%. During 1.067 MHz HIFU exposure of an agar tissue-mimicking material, cavitation activity is continuously monitored and quantified using a single-element broadband passive cavitation detector (PCD) positioned coaxially with the HIFU transducer. The HIFU amplitude is adaptively modulated in direct response to the PCD signal, making it possible to maintain cavitation activity and a temperature rise in excess of 30 °C for more than 30 s. Most importantly, the acoustic energy needed to achieve such focal heating is only a fraction of that required in the absence of cavitation control.

Key concepts: Cavitation, Transducer, Materials science, Acoustics, Duty cycle, Ultrasound, Physics, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Closed-loop adaptive feedback control of cavitation during high-intensity focussed ultrasound therapy. — Research Paper | ScholarLens