1990Applied OpticsRequires access

Operating characteristics of a tunable diode laser absorption spectrometer using short-external-cavity and DFB laser diodes

Brian F. Ventrudo, Daniel T. Cassidy

Open publisher page 21 citations

Abstract

Second harmonic detection at audio frequencies of isolated absorption lines with a laser absorption spectrometer employing AlGaAs and InGaAsP diode lasers, short external cavity (SXC) AlGaAs and InGaAsP diode lasers, and InGaAsP distributed feedback (DFB) diode lasers was investigated and compared. Noise levels equivalent to line center absorptions of ~3 x 10(-6) were achieved with each source. Single mode tuning ranges of 20-50 cm(-1) were obtained with both the SXC and DFB sources. The contamination of absorption spectra by suppressed laser side modes was identified and investigated as it relates to the identification of weak lines in the presence of strong lines.

About this research paper

What this paper is about

Second harmonic detection at audio frequencies of isolated absorption lines with a laser absorption spectrometer employing AlGaAs and InGaAsP diode lasers, short external cavity (SXC) AlGaAs and InGaAsP diode lasers, and InGaAsP distributed feedback (DFB) diode lasers was investigated and compared. Noise levels equivalent to line center absorptions of ~3 x 10(-6) were achieved with each source. Single mode tuning ranges of 20-50 cm(-1) were obtained with both the SXC and DFB sources. The contamination of absorption spectra by suppressed laser side modes was identified and investigated as it relates to the identification of weak lines in the presence of strong lines.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Second harmonic detection at audio frequencies of isolated absorption lines with a laser absorption spectrometer employing AlGaAs and InGaAsP diode lasers, short external cavity (SXC) AlGaAs and InGaAsP diode lasers, and InGaAsP distributed feedback (DFB) diode lasers was investigated and compared. Noise levels equivalent to line center absorptions of ~3 x 10(-6) were achieved with each source. Single mode tuning ranges of 20-50 cm(-1) were obtained with both the SXC and DFB sources. The contamination of absorption spectra by suppressed laser side modes was identified and investigated as it relates to the identification of weak lines in the presence of strong lines.

Key concepts: Laser, Tunable diode laser absorption spectroscopy, Materials science, Diode, Optoelectronics, Optics, Spectrometer, Absorption (acoustics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Operating characteristics of a tunable diode laser absorption spectrometer using short-external-cavity and DFB laser diodes — Research Paper | ScholarLens