2011•Saudi Journal of AnaesthesiaOpen access

A comparative study of efficacy of esmolol and fentanyl for pressure attenuation during laryngoscopy and endotracheal intubation

Shobhana Gupta, Purvi Tank

Open full text 47 citations

Abstract

OBJECTIVE: To compare the effectiveness of single bolus dose of esmolol or fentanyl in attenuating the hemodynamic responses during laryngoscopy and endotracheal intubation. METHODS: Ninety adult ASA I and ASA II patients were included in the study who underwent elective surgical procedures. Patients were divided into three groups. Group C (control) receiving 10 ml normal saline, group E (esmolol) receiving bolus dose of esmolol 2 mg/kg and group F (fentanyl) receiving bolus dose of fentanyl 2 µg/kg intravenously slowly. Study drug was injected 3 min before induction of anesthesia. Heart rate, systemic arterial pressure and ECG were recorded as baseline and after administration of study drug at intubation and 15 min thereafter. RESULTS: Reading of heart rate, blood pressure and rate pressure product were compared with baseline and among each group. The rise in heart rate was minimal in esmolol group and was highly significant. Also the rate pressure product at the time of intubation was minimal and was statistically significant rate 15 min thereafter in group E. CONCLUSION: Esmolol 2 mg/kg as a bolus done proved to be effective in attenuating rises in heart rate following laryngoscopy and intubation while the rise in blood pressure was suppressed but not abolished by bolus dose of esmolol.

About this research paper

What this paper is about

OBJECTIVE: To compare the effectiveness of single bolus dose of esmolol or fentanyl in attenuating the hemodynamic responses during laryngoscopy and endotracheal intubation. METHODS: Ninety adult ASA I and ASA II patients were included in the study who underwent elective surgical procedures. Patients were divided into three groups. Group C (control) receiving 10 ml normal saline, group E (esmolol) receiving bolus dose of esmolol 2 mg/kg and group F (fentanyl) receiving bolus dose of fentanyl 2 µg/kg intravenously slowly. Study drug was injected 3 min before induction of anesthesia. Heart rate, systemic arterial pressure and ECG were recorded as baseline and after administration of study drug at intubation and 15 min thereafter. RESULTS: Reading of heart rate, blood pressure and rate pressure product were compared with baseline and among each group. The rise in heart rate was minimal in esmolol group and was highly significant. Also the rate pressure product at the time of intubation was minimal and was statistically significant rate 15 min thereafter in group E. CONCLUSION: Esmolol 2 mg/kg as a bolus done proved to be effective in attenuating rises in heart rate following laryngoscopy and intubation while the rise in blood pressure was suppressed but not abolished by bolus dose of esmolol.

Why it matters

OpenAlex reports 47 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To compare the effectiveness of single bolus dose of esmolol or fentanyl in attenuating the hemodynamic responses during laryngoscopy and endotracheal intubation. METHODS: Ninety adult ASA I and ASA II patients were included in the study who underwent elective surgical procedures. Patients were divided into three groups. Group C (control) receiving 10 ml normal saline, group E (esmolol) receiving bolus dose of esmolol 2 mg/kg and group F (fentanyl) receiving bolus dose of fentanyl 2 µg/kg intravenously slowly. Study drug was injected 3 min before induction of anesthesia. Heart rate, systemic arterial pressure and ECG were recorded as baseline and after administration of study drug at intubation and 15 min thereafter. RESULTS: Reading of heart rate, blood pressure and rate pressure product were compared with baseline and among each group. The rise in heart rate was minimal in esmolol group and was highly significant. Also the rate pressure product at the time of intubation was minimal and was statistically significant rate 15 min thereafter in group E. CONCLUSION: Esmolol 2 mg/kg as a bolus done proved to be effective in attenuating rises in heart rate following laryngoscopy and intubation while the rise in blood pressure was suppressed but not abolished by bolus dose of esmolol.

Key concepts: Esmolol, Medicine, Fentanyl, Laryngoscopy, Endotracheal intubation, Anesthesia, Intubation, Blood pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparative study of efficacy of esmolol and fentanyl for pressure attenuation during laryngoscopy and endotracheal intubation — Research Paper | ScholarLens