Research on Calculation of Equivalent Damping Ratio of Electrical Transmission Tower-Line System with Viscoelastic Dampers
Cong Zeng, Dongxue Hao, Li Qun Hou
Abstract
Cong Zeng, Dongxue Hao, Li Qun Hou
Abstract
Installing viscoelastic dampers on electrical transmission tower will significantly reduce the wind-induced vibration response of electrical transmission tower-line system. On the basis of the concept of strain energy method with the combination of related codes and the theories of calculation for equivalent damping,a mothed is presented which is used to estimate the additional damping of electrical transmission tower-line system with viscoelastic dampers.Through a electrical transmission tower with viscoelastic dampers, based on the formula of strain energy in design code,this paper puts forward a calculation method of equivalent damping ratio based on the concept story of transmission tower,and through finite element model the responses of transmission tower with viscoelastic dampers model and the one with additional damping ratio model were compared.The simulation results show that the calculation method of equivalent damping ratio has high precision,and the errors are less than 5% in multi engineering conditions.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Installing viscoelastic dampers on electrical transmission tower will significantly reduce the wind-induced vibration response of electrical transmission tower-line system. On the basis of the concept of strain energy method with the combination of related codes and the theories of calculation for equivalent damping,a mothed is presented which is used to estimate the additional damping of electrical transmission tower-line system with viscoelastic dampers.Through a electrical transmission tower with viscoelastic dampers, based on the formula of strain energy in design code,this paper puts forward a calculation method of equivalent damping ratio based on the concept story of transmission tower,and through finite element model the responses of transmission tower with viscoelastic dampers model and the one with additional damping ratio model were compared.The simulation results show that the calculation method of equivalent damping ratio has high precision,and the errors are less than 5% in multi engineering conditions.
Key concepts: Damper, Viscoelasticity, Damping ratio, Structural engineering, Transmission tower, Tower, Transmission line, Electric power transmission