2012Advanced materials researchRequires access

Equilibrium Analysis of Hydrogen Adsorption on Activated Carbon

Qing Rong Zheng, Shuai Gao, Jie Chen

Open publisher page 0 citations

Abstract

For developing carbon based adsorbents for hydrogen storage, Staram PCTPro E&E was employed and activated carbon SAC-02 having specific surface area about 2074m2/g was selected to measure isotherms of hydrogen adsorption respectively from temperature range 77.15K-110.15K and 253.15K-293.15K. Isosteres of hydrogen adsorption on the activated carbon was then plotted to determine the isosteric heat of hydrogen adsorption, and temperature dependent of Henry law constants were further applied to set the limit isosteric heat of adsorption at zero surface coverage. Results show that the isosteric heat of adsorption is about 3.6-5.4kJ/mol with a mean value 4.38kJ/mol at zero surface coverage. Results also reveal that adsorption isosteres of adsorption data at different temperature regions bring about a different isosteric heat of adsorption due to the variation in contributions from thermal motion of adsorbate molecules. Conclusions are drawn that adsorption isosteres on the adsorption data in correspondence with the lowest and highest temperatures of the hydrogen storage system should be carried out to determine the isosteric heat of adsorption for effectively managing the thermal effect.

About this research paper

What this paper is about

For developing carbon based adsorbents for hydrogen storage, Staram PCTPro E&E was employed and activated carbon SAC-02 having specific surface area about 2074m2/g was selected to measure isotherms of hydrogen adsorption respectively from temperature range 77.15K-110.15K and 253.15K-293.15K. Isosteres of hydrogen adsorption on the activated carbon was then plotted to determine the isosteric heat of hydrogen adsorption, and temperature dependent of Henry law constants were further applied to set the limit isosteric heat of adsorption at zero surface coverage. Results show that the isosteric heat of adsorption is about 3.6-5.4kJ/mol with a mean value 4.38kJ/mol at zero surface coverage. Results also reveal that adsorption isosteres of adsorption data at different temperature regions bring about a different isosteric heat of adsorption due to the variation in contributions from thermal motion of adsorbate molecules. Conclusions are drawn that adsorption isosteres on the adsorption data in correspondence with the lowest and highest temperatures of the hydrogen storage system should be carried out to determine the isosteric heat of adsorption for effectively managing the thermal effect.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For developing carbon based adsorbents for hydrogen storage, Staram PCTPro E&E was employed and activated carbon SAC-02 having specific surface area about 2074m2/g was selected to measure isotherms of hydrogen adsorption respectively from temperature range 77.15K-110.15K and 253.15K-293.15K. Isosteres of hydrogen adsorption on the activated carbon was then plotted to determine the isosteric heat of hydrogen adsorption, and temperature dependent of Henry law constants were further applied to set the limit isosteric heat of adsorption at zero surface coverage. Results show that the isosteric heat of adsorption is about 3.6-5.4kJ/mol with a mean value 4.38kJ/mol at zero surface coverage. Results also reveal that adsorption isosteres of adsorption data at different temperature regions bring about a different isosteric heat of adsorption due to the variation in contributions from thermal motion of adsorbate molecules. Conclusions are drawn that adsorption isosteres on the adsorption data in correspondence with the lowest and highest temperatures of the hydrogen storage system should be carried out to determine the isosteric heat of adsorption for effectively managing the thermal effect.

Key concepts: Adsorption, Activated carbon, Hydrogen, Chemistry, Thermodynamics, Carbon fibers, Atmospheric temperature range, Molecule

Related papers

Back to paper searchBrowse research topicsOriginal source
Equilibrium Analysis of Hydrogen Adsorption on Activated Carbon — Research Paper | ScholarLens