1993European Transactions on Electrical PowerRequires access

Basic areas of research preceding design and commissioning of 1200 kV AC power transmission lines: Some key problems and solutions

N.N. Tikhodeev

Open publisher page 0 citations

Abstract

Abstract In the paper is reported the experience of studies that preceded the planning, construction and operation of 1200 kV lines in Russia and Kazakhstan in the former USSR in areas peculiar to UHV power transmission, including the switching surge dielectric strength of long air gaps, selection of line insulation, profound limitation of resonance and switching overvoltages, environmental effects, corona losses of bundles with eight and more subconductors, radio interference. Both implemented and contemplated alternatives of UHV lines are discussed.

About this research paper

What this paper is about

Abstract In the paper is reported the experience of studies that preceded the planning, construction and operation of 1200 kV lines in Russia and Kazakhstan in the former USSR in areas peculiar to UHV power transmission, including the switching surge dielectric strength of long air gaps, selection of line insulation, profound limitation of resonance and switching overvoltages, environmental effects, corona losses of bundles with eight and more subconductors, radio interference. Both implemented and contemplated alternatives of UHV lines are discussed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract In the paper is reported the experience of studies that preceded the planning, construction and operation of 1200 kV lines in Russia and Kazakhstan in the former USSR in areas peculiar to UHV power transmission, including the switching surge dielectric strength of long air gaps, selection of line insulation, profound limitation of resonance and switching overvoltages, environmental effects, corona losses of bundles with eight and more subconductors, radio interference. Both implemented and contemplated alternatives of UHV lines are discussed.

Key concepts: Electric power transmission, Electrical engineering, Transmission line, Engineering, Power transmission, Line (geometry), Ground, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Basic areas of research preceding design and commissioning of 1200 kV AC power transmission lines: Some key problems and solutions — Research Paper | ScholarLens