1975•IEEE Transactions on Nuclear ScienceRequires access

Neutron Diagnostics for Pulsed Plasma Sources

Frank C. Young

Open publisher page 22 citations

Abstract

Neutron detectors have been developed and applied to a variety of pulsed plasma sources with intensities ranging from 102 to 1012 neutrons/pulse. For yields as small as 102 neutrons, a 6Li-glass-scintillator detector is used. A rhodium-activation counter has been developed for yields greater than 106 neutrons. These detectors are used for total yield and angular distribution measurements. Neutron energies are determined primarily by the time-of-flight technique. Limitations on this technique for neutron yield and energy measurements are discussed. Improved methods are needed to measure the spatial extent of these neutron sources.

About this research paper

What this paper is about

Neutron detectors have been developed and applied to a variety of pulsed plasma sources with intensities ranging from 102 to 1012 neutrons/pulse. For yields as small as 102 neutrons, a 6Li-glass-scintillator detector is used. A rhodium-activation counter has been developed for yields greater than 106 neutrons. These detectors are used for total yield and angular distribution measurements. Neutron energies are determined primarily by the time-of-flight technique. Limitations on this technique for neutron yield and energy measurements are discussed. Improved methods are needed to measure the spatial extent of these neutron sources.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Neutron detectors have been developed and applied to a variety of pulsed plasma sources with intensities ranging from 102 to 1012 neutrons/pulse. For yields as small as 102 neutrons, a 6Li-glass-scintillator detector is used. A rhodium-activation counter has been developed for yields greater than 106 neutrons. These detectors are used for total yield and angular distribution measurements. Neutron energies are determined primarily by the time-of-flight technique. Limitations on this technique for neutron yield and energy measurements are discussed. Improved methods are needed to measure the spatial extent of these neutron sources.

Key concepts: Neutron, Scintillator, Neutron detection, Neutron source, Neutron emission, Neutron probe, Nuclear physics, Detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Neutron Diagnostics for Pulsed Plasma Sources — Research Paper | ScholarLens