2012Pharmaceutical Development and TechnologyRequires access

Application of external lubrication during the roller compaction of adhesive pharmaceutical formulations

Jason Dawes, Carl Allenspach, John F. Gamble, Richard Greenwood, Phil Robbins, Mike Tobyn

Open publisher page 12 citations

Abstract

A novel use of external lubrication has been investigated in which magnesium stearate was applied directly to the roll surface during roller compaction. A scalable parameter; travelling roll distance per shot (D(pS)), has been defined which ensures that an equal amount of magnesium stearate is applied to the roll surface per rotation at any roll speed. It was found that a formulation containing 20% w/w of either the API Pravastatin or Ibipinabant required a smaller D(pS) than a placebo formulation in order to prevent roll adherence. The inherent adhesiveness, and hence the required amount of external magnesium stearate to prevent roll adhesion, will depend on the material properties of the formulation. The amount of magnesium stearate transferred from the roll surface to the ribbon was measured using inductively coupled plasma optical emission spectroscopy and was found to be less than 0.01% w/w. This is a significant reduction in magnesium stearate compared to the normal manufacturing procedure of blending 0.25-2.0% w/w within the formulation.The advantage of external lubrication during roller compaction is the significant reduction in magnesium stearate from the formulation which could lead to the production of tablets with superior mechanical properties and faster dissolution times.

About this research paper

What this paper is about

A novel use of external lubrication has been investigated in which magnesium stearate was applied directly to the roll surface during roller compaction. A scalable parameter; travelling roll distance per shot (D(pS)), has been defined which ensures that an equal amount of magnesium stearate is applied to the roll surface per rotation at any roll speed. It was found that a formulation containing 20% w/w of either the API Pravastatin or Ibipinabant required a smaller D(pS) than a placebo formulation in order to prevent roll adherence. The inherent adhesiveness, and hence the required amount of external magnesium stearate to prevent roll adhesion, will depend on the material properties of the formulation. The amount of magnesium stearate transferred from the roll surface to the ribbon was measured using inductively coupled plasma optical emission spectroscopy and was found to be less than 0.01% w/w. This is a significant reduction in magnesium stearate compared to the normal manufacturing procedure of blending 0.25-2.0% w/w within the formulation.The advantage of external lubrication during roller compaction is the significant reduction in magnesium stearate from the formulation which could lead to the production of tablets with superior mechanical properties and faster dissolution times.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel use of external lubrication has been investigated in which magnesium stearate was applied directly to the roll surface during roller compaction. A scalable parameter; travelling roll distance per shot (D(pS)), has been defined which ensures that an equal amount of magnesium stearate is applied to the roll surface per rotation at any roll speed. It was found that a formulation containing 20% w/w of either the API Pravastatin or Ibipinabant required a smaller D(pS) than a placebo formulation in order to prevent roll adherence. The inherent adhesiveness, and hence the required amount of external magnesium stearate to prevent roll adhesion, will depend on the material properties of the formulation. The amount of magnesium stearate transferred from the roll surface to the ribbon was measured using inductively coupled plasma optical emission spectroscopy and was found to be less than 0.01% w/w. This is a significant reduction in magnesium stearate compared to the normal manufacturing procedure of blending 0.25-2.0% w/w within the formulation.The advantage of external lubrication during roller compaction is the significant reduction in magnesium stearate from the formulation which could lead to the production of tablets with superior mechanical properties and faster dissolution times.

Key concepts: Magnesium stearate, Lubrication, Zinc stearate, Materials science, Compaction, Magnesium, Dissolution, Extrusion

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of external lubrication during the roller compaction of adhesive pharmaceutical formulations — Research Paper | ScholarLens