2010Rapid Communications in Mass SpectrometryRequires access

Theoretical calculations for mass resolution of a quadrupole ion trap reflectron time‐of‐flight mass spectrometer

Chang Min Choi, Jiyoung Heo, Chang Joon Park, Nam Joon Kim

Open publisher page 5 citations

Abstract

We have developed a theoretical method of predicting the mass resolution for a quadrupole ion trap reflectron time-of-flight (QIT-reTOF) mass spectrometer as a function of the spatial and velocity distributions of ions, voltages applied to the electrodes, and dimensions of the instrument. The flight times of ions were calculated using theoretical equations derived with an assumption of uniform electric fields inside the QIT and with the analytical description of the potential including the monopole, dipole, and quadrupole components. The mass resolution was then estimated from the flight-time spread of the ions with finite spatial and velocity distributions inside the QIT. The feasibility of the theoretical method was confirmed by the reasonable agreement of the theoretical resolution with the experimental one measured by varying the extraction voltage of the QIT or the deceleration voltage of the reflectron. We found that the theoretical resolution estimated with the assumption of the uniform electric fields inside the QIT reproduced the experimental one better than that with the analytical description of the potential. The possible applications of this theoretical method include the optimization of the experimental parameters of a given QIT-reTOF mass spectrometer and the design of new instruments with higher mass resolution.

About this research paper

What this paper is about

We have developed a theoretical method of predicting the mass resolution for a quadrupole ion trap reflectron time-of-flight (QIT-reTOF) mass spectrometer as a function of the spatial and velocity distributions of ions, voltages applied to the electrodes, and dimensions of the instrument. The flight times of ions were calculated using theoretical equations derived with an assumption of uniform electric fields inside the QIT and with the analytical description of the potential including the monopole, dipole, and quadrupole components. The mass resolution was then estimated from the flight-time spread of the ions with finite spatial and velocity distributions inside the QIT. The feasibility of the theoretical method was confirmed by the reasonable agreement of the theoretical resolution with the experimental one measured by varying the extraction voltage of the QIT or the deceleration voltage of the reflectron. We found that the theoretical resolution estimated with the assumption of the uniform electric fields inside the QIT reproduced the experimental one better than that with the analytical description of the potential. The possible applications of this theoretical method include the optimization of the experimental parameters of a given QIT-reTOF mass spectrometer and the design of new instruments with higher mass resolution.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a theoretical method of predicting the mass resolution for a quadrupole ion trap reflectron time-of-flight (QIT-reTOF) mass spectrometer as a function of the spatial and velocity distributions of ions, voltages applied to the electrodes, and dimensions of the instrument. The flight times of ions were calculated using theoretical equations derived with an assumption of uniform electric fields inside the QIT and with the analytical description of the potential including the monopole, dipole, and quadrupole components. The mass resolution was then estimated from the flight-time spread of the ions with finite spatial and velocity distributions inside the QIT. The feasibility of the theoretical method was confirmed by the reasonable agreement of the theoretical resolution with the experimental one measured by varying the extraction voltage of the QIT or the deceleration voltage of the reflectron. We found that the theoretical resolution estimated with the assumption of the uniform electric fields inside the QIT reproduced the experimental one better than that with the analytical description of the potential. The possible applications of this theoretical method include the optimization of the experimental parameters of a given QIT-reTOF mass spectrometer and the design of new instruments with higher mass resolution.

Key concepts: Reflectron, Chemistry, Hybrid mass spectrometer, Mass spectrometry, Ion trap, Time of flight, Quadrupole mass analyzer, Quadrupole ion trap

Related papers

Back to paper searchBrowse research topicsOriginal source
Theoretical calculations for mass resolution of a quadrupole ion trap reflectron time‐of‐flight mass spectrometer — Research Paper | ScholarLens