Intraocular Pressure and the Corneal Endothelium After Neodymium-YAG Laser Posterior Capsulotomy
Manus C. Kraff
Abstract
Manus C. Kraff
Abstract
We studied intraocular pressure (IOP) changes and specular microscopic findings in 118 consecutive neodymium-YAG laser posterior capsulotomy procedures; 37 cases were aphakic, and 81 were pseudophakic. There was a significantly greater rise in IOP one hour after Nd-YAG laser treatment in the aphakic group than in the pseudophakic group (8.2 mm Hg vs 3.5 mm Hg, respectively). At one week postoperatively, IOPs in the aphakic group were still significantly elevated over baseline levels (3.6 mm Hg), while those in the pseudophakic group had returned to baseline levels. Differences in treatment between the aphakic and pseudophakic groups in total number of pulses, average energy, and total energy did not explain the differences in IOP. No significant change in endothelial cell densities was seen between pretreatment measurements and those taken one week after Nd-YAG laser treatment.
OpenAlex reports 68 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We studied intraocular pressure (IOP) changes and specular microscopic findings in 118 consecutive neodymium-YAG laser posterior capsulotomy procedures; 37 cases were aphakic, and 81 were pseudophakic. There was a significantly greater rise in IOP one hour after Nd-YAG laser treatment in the aphakic group than in the pseudophakic group (8.2 mm Hg vs 3.5 mm Hg, respectively). At one week postoperatively, IOPs in the aphakic group were still significantly elevated over baseline levels (3.6 mm Hg), while those in the pseudophakic group had returned to baseline levels. Differences in treatment between the aphakic and pseudophakic groups in total number of pulses, average energy, and total energy did not explain the differences in IOP. No significant change in endothelial cell densities was seen between pretreatment measurements and those taken one week after Nd-YAG laser treatment.
Key concepts: Posterior Capsulotomy, Intraocular pressure, Ophthalmology, Capsulotomy, Medicine, Laser, Corneal endothelium, Intraocular lenses