1989CirculationOpen access

Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.

Jonathan M. Tobis, John Mallery, James Gessert, Jim Griffith, Don Mahon, Matthew Bessen, M Moriuchi, L McLeay, Michael P. McRae, Walter L. Henry

Open full text 297 citations

Abstract

A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear demarcation between the lumen and the endothelium, the atheroma plaque, the muscular media, and the adventitia. Qualitative characteristics of plaque disruption, dissection, and residual flaps were readily visible. In addition, quantitative information about cross-sectional lumen area was obtained before and after balloon dilatation. The mean cross-sectional lumen area increased from 8.7 to 15.1 mm2 (p less than 0.01) following balloon dilatation. The lumen area measured from the ultrasound images following dilatation correlated closely with the area measured from histologic sections (r = 0.88). The results from this study indicate that a small-diameter ultrasound imaging catheter can be developed that will provide high-resolution qualitative and quantitative information during peripheral and coronary angioplasty.

About this research paper

What this paper is about

A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear demarcation between the lumen and the endothelium, the atheroma plaque, the muscular media, and the adventitia. Qualitative characteristics of plaque disruption, dissection, and residual flaps were readily visible. In addition, quantitative information about cross-sectional lumen area was obtained before and after balloon dilatation. The mean cross-sectional lumen area increased from 8.7 to 15.1 mm2 (p less than 0.01) following balloon dilatation. The lumen area measured from the ultrasound images following dilatation correlated closely with the area measured from histologic sections (r = 0.88). The results from this study indicate that a small-diameter ultrasound imaging catheter can be developed that will provide high-resolution qualitative and quantitative information during peripheral and coronary angioplasty.

Why it matters

OpenAlex reports 297 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear demarcation between the lumen and the endothelium, the atheroma plaque, the muscular media, and the adventitia. Qualitative characteristics of plaque disruption, dissection, and residual flaps were readily visible. In addition, quantitative information about cross-sectional lumen area was obtained before and after balloon dilatation. The mean cross-sectional lumen area increased from 8.7 to 15.1 mm2 (p less than 0.01) following balloon dilatation. The lumen area measured from the ultrasound images following dilatation correlated closely with the area measured from histologic sections (r = 0.88). The results from this study indicate that a small-diameter ultrasound imaging catheter can be developed that will provide high-resolution qualitative and quantitative information during peripheral and coronary angioplasty.

Key concepts: Medicine, Lumen (anatomy), Angioplasty, Balloon, Intravascular ultrasound, Ultrasound, Radiology, Adventitia

Related papers

Back to paper searchBrowse research topicsOriginal source
Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro. — Research Paper | ScholarLens