2005•Rapid Communications in Mass SpectrometryRequires access

Absolute isotopic composition and atomic weight of neodymium using thermal ionization mass spectrometry

Mo‐Tian Zhao, Tao Zhou, Jun Wang, H. J. Lü, Xiang Fang, Chunhua Guo, Qiuli Li, Chao-Feng Li

Open publisher page 5 citations

Abstract

Synthetic mixtures prepared gravimetrically from highly enriched isotopes of neodymium in the form of oxides of well-defined purity were used to calibrate a thermal ionization mass spectrometer. A new error analysis was applied to calculate the final uncertainty of the atomic weight value. Measurements on natural neodymium samples yielded an absolute isotopic composition of 27.153(19) atomic percent (at.%) 142Nd, 12.173(18) at.% 143Nd, 23.798(12) at.% 144Nd, 8.293(7) at.% 145Nd, 17.189(17) at.% 146Nd, 5.756(8) at.% 148Nd, and 5.638(9) at.% 150Nd, and the atomic weight of neodymium as 144.2415(13), with uncertainties given on the basis of 95% confidence limits. No isotopic fractionation was found in terrestrial neodymium materials.

About this research paper

What this paper is about

Synthetic mixtures prepared gravimetrically from highly enriched isotopes of neodymium in the form of oxides of well-defined purity were used to calibrate a thermal ionization mass spectrometer. A new error analysis was applied to calculate the final uncertainty of the atomic weight value. Measurements on natural neodymium samples yielded an absolute isotopic composition of 27.153(19) atomic percent (at.%) 142Nd, 12.173(18) at.% 143Nd, 23.798(12) at.% 144Nd, 8.293(7) at.% 145Nd, 17.189(17) at.% 146Nd, 5.756(8) at.% 148Nd, and 5.638(9) at.% 150Nd, and the atomic weight of neodymium as 144.2415(13), with uncertainties given on the basis of 95% confidence limits. No isotopic fractionation was found in terrestrial neodymium materials.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Synthetic mixtures prepared gravimetrically from highly enriched isotopes of neodymium in the form of oxides of well-defined purity were used to calibrate a thermal ionization mass spectrometer. A new error analysis was applied to calculate the final uncertainty of the atomic weight value. Measurements on natural neodymium samples yielded an absolute isotopic composition of 27.153(19) atomic percent (at.%) 142Nd, 12.173(18) at.% 143Nd, 23.798(12) at.% 144Nd, 8.293(7) at.% 145Nd, 17.189(17) at.% 146Nd, 5.756(8) at.% 148Nd, and 5.638(9) at.% 150Nd, and the atomic weight of neodymium as 144.2415(13), with uncertainties given on the basis of 95% confidence limits. No isotopic fractionation was found in terrestrial neodymium materials.

Key concepts: Neodymium, Chemistry, Fractionation, Mass spectrometry, Atomic mass, Analytical Chemistry (journal), Ionization, Isotope

Related papers

Back to paper searchBrowse research topicsOriginal source
Absolute isotopic composition and atomic weight of neodymium using thermal ionization mass spectrometry — Research Paper | ScholarLens