Acoustic measurements of the thermodynamic temperature between the triple point of mercury and 380 K
G. Benedetto, R. M. Gavioso, R. Spagnolo, P Marcarino, Andrea Merlone
Abstract
Open-access reader
G. Benedetto, R. M. Gavioso, R. Spagnolo, P Marcarino, Andrea Merlone
Abstract
Open-access reader
We have measured the differences between the Kelvin thermodynamic temperature and the temperature of the International Temperature Scale of 1990 on nine isotherms between the triple point of mercury and 380 K, by means of a primary acoustic thermometer. For the present measurements the standard uncertainty of ( T − T 90 ) ranges from 0.9 mK at 234 K to 1.7 mK at 380 K. The experimental method is based on the measurement of the acoustic resonance frequencies of an argon-filled spherical cavity and the microwave resonance frequencies of the same cavity when evacuated. The present results agree within the remarkably small combined uncertainties with both NIST acoustic thermometry ([1] Moldover M R et al 1999 J. Res. Natl Inst. Stand. Technol. 104 11–46; [2] Strouse G F et al 2002 Progress in primary acoustic thermometry at NIST: 273 K to 505 K 8th Temperature Symp. (Chicago, 21–24 October 2002) ) and UCL acoustic thermometry ([3] Ewing M B and Trusler J P M 2000 J. Chem. Thermodyn. 32 1229–55) in the overlapping temperature range.
OpenAlex reports 98 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have measured the differences between the Kelvin thermodynamic temperature and the temperature of the International Temperature Scale of 1990 on nine isotherms between the triple point of mercury and 380 K, by means of a primary acoustic thermometer. For the present measurements the standard uncertainty of ( T − T 90 ) ranges from 0.9 mK at 234 K to 1.7 mK at 380 K. The experimental method is based on the measurement of the acoustic resonance frequencies of an argon-filled spherical cavity and the microwave resonance frequencies of the same cavity when evacuated. The present results agree within the remarkably small combined uncertainties with both NIST acoustic thermometry ([1] Moldover M R et al 1999 J. Res. Natl Inst. Stand. Technol. 104 11–46; [2] Strouse G F et al 2002 Progress in primary acoustic thermometry at NIST: 273 K to 505 K 8th Temperature Symp. (Chicago, 21–24 October 2002) ) and UCL acoustic thermometry ([3] Ewing M B and Trusler J P M 2000 J. Chem. Thermodyn. 32 1229–55) in the overlapping temperature range.
Key concepts: Thermodynamic temperature, Triple point, International Temperature Scale of 1990, Atmospheric temperature range, Thermometer, Scale of temperature, Temperature measurement, Materials science