Objektive Noniussehschärfenprüfung bei Erwachsenen, Kindern und Kleinkindern - Möglichkeiten und Grenzen einer neuen Methode

Michael Gräf, Heidrun Dietrich

Open publisher page 3 citations

Abstract

BACKGROUND: Recently, a method of objective Vernier acuity testing using a modified Catford drum was presented. A tight correlation between the objective Vernier acuity and the Snellen acuity was reported (Hopkisson et al. 1991). PATIENTS AND METHODS: In 41 cooperative patients with strabismic amblyopia and 20 normal subjects were compared the subjective Landolt acuity with the objective Vernier acuity and the individual interocular differences of the objective Vernier acuity. The Vernier method was then tested in 44 healthy 6- to 36-months-old infants. In 39 of the amblyopic and 15 of the normal subjects we compared the Landolt acuity with the grating acuity as measured with the Teller-acuity-card-test, and the interocular differences of the grating acuity. The Vernier target was a black line with an offset of one fifth of its thickness. In a distance of 1 m the offset appeared under visual angles of 15.9' to 0.3' corresponding to acuities of 0.06 to 3.2. The line was moving back and forth in its longitudinal direction. The objective Vernier acuity was defined by the smallest offset causing pursuit eye movements. RESULTS: Strabismic amblyopia was detected by the Vernier method with a sensitivity of 54%. In infants, however, the sensitivity would be less than 30%. In both eyes only 45% of the infants could be tested at all. The sensitivity of the Teller-acuity-card-test was 28%. CONCLUSION: Many cases of strabismic amblyopia will escape detection by the described method of Vernier acuity testing.

About this research paper

What this paper is about

BACKGROUND: Recently, a method of objective Vernier acuity testing using a modified Catford drum was presented. A tight correlation between the objective Vernier acuity and the Snellen acuity was reported (Hopkisson et al. 1991). PATIENTS AND METHODS: In 41 cooperative patients with strabismic amblyopia and 20 normal subjects were compared the subjective Landolt acuity with the objective Vernier acuity and the individual interocular differences of the objective Vernier acuity. The Vernier method was then tested in 44 healthy 6- to 36-months-old infants. In 39 of the amblyopic and 15 of the normal subjects we compared the Landolt acuity with the grating acuity as measured with the Teller-acuity-card-test, and the interocular differences of the grating acuity. The Vernier target was a black line with an offset of one fifth of its thickness. In a distance of 1 m the offset appeared under visual angles of 15.9' to 0.3' corresponding to acuities of 0.06 to 3.2. The line was moving back and forth in its longitudinal direction. The objective Vernier acuity was defined by the smallest offset causing pursuit eye movements. RESULTS: Strabismic amblyopia was detected by the Vernier method with a sensitivity of 54%. In infants, however, the sensitivity would be less than 30%. In both eyes only 45% of the infants could be tested at all. The sensitivity of the Teller-acuity-card-test was 28%. CONCLUSION: Many cases of strabismic amblyopia will escape detection by the described method of Vernier acuity testing.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Recently, a method of objective Vernier acuity testing using a modified Catford drum was presented. A tight correlation between the objective Vernier acuity and the Snellen acuity was reported (Hopkisson et al. 1991). PATIENTS AND METHODS: In 41 cooperative patients with strabismic amblyopia and 20 normal subjects were compared the subjective Landolt acuity with the objective Vernier acuity and the individual interocular differences of the objective Vernier acuity. The Vernier method was then tested in 44 healthy 6- to 36-months-old infants. In 39 of the amblyopic and 15 of the normal subjects we compared the Landolt acuity with the grating acuity as measured with the Teller-acuity-card-test, and the interocular differences of the grating acuity. The Vernier target was a black line with an offset of one fifth of its thickness. In a distance of 1 m the offset appeared under visual angles of 15.9' to 0.3' corresponding to acuities of 0.06 to 3.2. The line was moving back and forth in its longitudinal direction. The objective Vernier acuity was defined by the smallest offset causing pursuit eye movements. RESULTS: Strabismic amblyopia was detected by the Vernier method with a sensitivity of 54%. In infants, however, the sensitivity would be less than 30%. In both eyes only 45% of the infants could be tested at all. The sensitivity of the Teller-acuity-card-test was 28%. CONCLUSION: Many cases of strabismic amblyopia will escape detection by the described method of Vernier acuity testing.

Key concepts: Vernier acuity, Visual acuity, Vernier scale, Medicine, Ophthalmology, Optometry, Optics, Physics