Objektive Noniussehschärfenprüfung bei Erwachsenen, Kindern und Kleinkindern - Möglichkeiten und Grenzen einer neuen Methode
Michael Gräf, Heidrun Dietrich
Abstract
Michael Gräf, Heidrun Dietrich
Abstract
BACKGROUND: Recently, a method of objective Vernier acuity testing using a modified Catford drum was presented. A tight correlation between the objective Vernier acuity and the Snellen acuity was reported (Hopkisson et al. 1991). PATIENTS AND METHODS: In 41 cooperative patients with strabismic amblyopia and 20 normal subjects were compared the subjective Landolt acuity with the objective Vernier acuity and the individual interocular differences of the objective Vernier acuity. The Vernier method was then tested in 44 healthy 6- to 36-months-old infants. In 39 of the amblyopic and 15 of the normal subjects we compared the Landolt acuity with the grating acuity as measured with the Teller-acuity-card-test, and the interocular differences of the grating acuity. The Vernier target was a black line with an offset of one fifth of its thickness. In a distance of 1 m the offset appeared under visual angles of 15.9' to 0.3' corresponding to acuities of 0.06 to 3.2. The line was moving back and forth in its longitudinal direction. The objective Vernier acuity was defined by the smallest offset causing pursuit eye movements. RESULTS: Strabismic amblyopia was detected by the Vernier method with a sensitivity of 54%. In infants, however, the sensitivity would be less than 30%. In both eyes only 45% of the infants could be tested at all. The sensitivity of the Teller-acuity-card-test was 28%. CONCLUSION: Many cases of strabismic amblyopia will escape detection by the described method of Vernier acuity testing.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: Recently, a method of objective Vernier acuity testing using a modified Catford drum was presented. A tight correlation between the objective Vernier acuity and the Snellen acuity was reported (Hopkisson et al. 1991). PATIENTS AND METHODS: In 41 cooperative patients with strabismic amblyopia and 20 normal subjects were compared the subjective Landolt acuity with the objective Vernier acuity and the individual interocular differences of the objective Vernier acuity. The Vernier method was then tested in 44 healthy 6- to 36-months-old infants. In 39 of the amblyopic and 15 of the normal subjects we compared the Landolt acuity with the grating acuity as measured with the Teller-acuity-card-test, and the interocular differences of the grating acuity. The Vernier target was a black line with an offset of one fifth of its thickness. In a distance of 1 m the offset appeared under visual angles of 15.9' to 0.3' corresponding to acuities of 0.06 to 3.2. The line was moving back and forth in its longitudinal direction. The objective Vernier acuity was defined by the smallest offset causing pursuit eye movements. RESULTS: Strabismic amblyopia was detected by the Vernier method with a sensitivity of 54%. In infants, however, the sensitivity would be less than 30%. In both eyes only 45% of the infants could be tested at all. The sensitivity of the Teller-acuity-card-test was 28%. CONCLUSION: Many cases of strabismic amblyopia will escape detection by the described method of Vernier acuity testing.
Key concepts: Vernier acuity, Visual acuity, Vernier scale, Medicine, Ophthalmology, Optometry, Optics, Physics