An infrared interferometer for investigating subthermonuclear plasma in the GOL-3 multimirror trap

Vladimir S. Burmasov, V.B. Bobylev, Alina A. Ivanova, S. V. Ivanenko, A. A. Kasatov, Dmitrii A. Kasatov, Edward P. Kruglyakov, Konstantin N. Kuklin, Сергей Сергеевич Попов, Vladimir V. Postupaev, E. A. Puryga, A. F. Rovenskikh, Vladislav F. Sklyarov

Open publisher page 6 citations

Abstract

A simple Michelson CO2 interferometer for measuring the high-temperature plasma density within one interference fringe (n e l = 1016 cm−2) at two points (0.8 and 9.0 m) of the long (L = 12 m) GOL-3 corrugated trap was used. A piezoelectric element that provides displacements of the mirror in the reference arm of the interferometer is used to calibrate the interferometer and perform remote control of the initial measurement phase. The interferometer is manufactured from dielectric materials, thus excluding a mechanical action of stray magnetic fields on its elements. The time resolution of the interferometer is determined by a HgCdTe diode and equals ∼1 ns. The sensitivity of the interferometer is ∼5 × 10−4 of a fringe (n e l = 2 × 1013 cm−2).

About this research paper

What this paper is about

A simple Michelson CO2 interferometer for measuring the high-temperature plasma density within one interference fringe (n e l = 1016 cm−2) at two points (0.8 and 9.0 m) of the long (L = 12 m) GOL-3 corrugated trap was used. A piezoelectric element that provides displacements of the mirror in the reference arm of the interferometer is used to calibrate the interferometer and perform remote control of the initial measurement phase. The interferometer is manufactured from dielectric materials, thus excluding a mechanical action of stray magnetic fields on its elements. The time resolution of the interferometer is determined by a HgCdTe diode and equals ∼1 ns. The sensitivity of the interferometer is ∼5 × 10−4 of a fringe (n e l = 2 × 1013 cm−2).

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple Michelson CO2 interferometer for measuring the high-temperature plasma density within one interference fringe (n e l = 1016 cm−2) at two points (0.8 and 9.0 m) of the long (L = 12 m) GOL-3 corrugated trap was used. A piezoelectric element that provides displacements of the mirror in the reference arm of the interferometer is used to calibrate the interferometer and perform remote control of the initial measurement phase. The interferometer is manufactured from dielectric materials, thus excluding a mechanical action of stray magnetic fields on its elements. The time resolution of the interferometer is determined by a HgCdTe diode and equals ∼1 ns. The sensitivity of the interferometer is ∼5 × 10−4 of a fringe (n e l = 2 × 1013 cm−2).

Key concepts: Interferometry, Michelson interferometer, Interferometric visibility, Interference (communication), Optics, Astronomical interferometer, Physics, Intensity interferometer

Related papers

Back to paper searchBrowse research topicsOriginal source
An infrared interferometer for investigating subthermonuclear plasma in the GOL-3 multimirror trap — Research Paper | ScholarLens