1986CirculationRequires access

The effect of chemical ablation of the endocardium on ventricular fibrillation threshold.

R J Damiano, P K Smith, Henry F. Tripp, Tetsuo Asano, Kent W. Small, J. E. Lowe, R.E. Ideker, James L. Cox

Open publisher page 53 citations

Abstract

The purpose of this study was to examine the effects of ablation of the superficial endocardium and Purkinje network on left ventricular fibrillation threshold. Lugol's solution was applied through small ventriculotomies to the left and right ventricular endocardium of 10 dogs on cardiopulmonary bypass. Two control groups of five animals each underwent either endocardial application of saline or epicardial application of Lugol's solution. Ventricular fibrillation threshold was measured before and after each intervention by the single-stimulus technique. Application of Lugol's solution to the endocardium resulted in a 102 +/- 15% increase in ventricular fibrillation threshold from a control value of 26 +/- 2 to 53 +/- 6 mA (p less than .005). In two animals, ventricular fibrillation could not be initiated postoperatively. In the control groups, there were no significant changes in ventricular fibrillation threshold. Histologic examination revealed that Lugol's solution obliterated less than 0.5 mm of superficial endocardium while sparing the adjacent myocardium. Electrophysiologic and rheologic data confirmed the discrete nature of the chemical injury. Thus ablation of the superficial ventricular endocardium with Lugol's solution results in a profound increase in the ventricular fibrillation threshold with only minimal tissue destruction.

About this research paper

What this paper is about

The purpose of this study was to examine the effects of ablation of the superficial endocardium and Purkinje network on left ventricular fibrillation threshold. Lugol's solution was applied through small ventriculotomies to the left and right ventricular endocardium of 10 dogs on cardiopulmonary bypass. Two control groups of five animals each underwent either endocardial application of saline or epicardial application of Lugol's solution. Ventricular fibrillation threshold was measured before and after each intervention by the single-stimulus technique. Application of Lugol's solution to the endocardium resulted in a 102 +/- 15% increase in ventricular fibrillation threshold from a control value of 26 +/- 2 to 53 +/- 6 mA (p less than .005). In two animals, ventricular fibrillation could not be initiated postoperatively. In the control groups, there were no significant changes in ventricular fibrillation threshold. Histologic examination revealed that Lugol's solution obliterated less than 0.5 mm of superficial endocardium while sparing the adjacent myocardium. Electrophysiologic and rheologic data confirmed the discrete nature of the chemical injury. Thus ablation of the superficial ventricular endocardium with Lugol's solution results in a profound increase in the ventricular fibrillation threshold with only minimal tissue destruction.

Why it matters

OpenAlex reports 53 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to examine the effects of ablation of the superficial endocardium and Purkinje network on left ventricular fibrillation threshold. Lugol's solution was applied through small ventriculotomies to the left and right ventricular endocardium of 10 dogs on cardiopulmonary bypass. Two control groups of five animals each underwent either endocardial application of saline or epicardial application of Lugol's solution. Ventricular fibrillation threshold was measured before and after each intervention by the single-stimulus technique. Application of Lugol's solution to the endocardium resulted in a 102 +/- 15% increase in ventricular fibrillation threshold from a control value of 26 +/- 2 to 53 +/- 6 mA (p less than .005). In two animals, ventricular fibrillation could not be initiated postoperatively. In the control groups, there were no significant changes in ventricular fibrillation threshold. Histologic examination revealed that Lugol's solution obliterated less than 0.5 mm of superficial endocardium while sparing the adjacent myocardium. Electrophysiologic and rheologic data confirmed the discrete nature of the chemical injury. Thus ablation of the superficial ventricular endocardium with Lugol's solution results in a profound increase in the ventricular fibrillation threshold with only minimal tissue destruction.

Key concepts: Endocardium, Ventricular fibrillation, Medicine, Cardiology, Ablation, Internal medicine, Fibrillation, Cardiopulmonary bypass

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of chemical ablation of the endocardium on ventricular fibrillation threshold. — Research Paper | ScholarLens