1976Cardiovascular ResearchRequires access

Hot film coronary artery velocity measurements in horses

Robert M. Nerem, John A. Rumberger, D. R. Gross, William W. Muir, GARY L. GEIGER

Open publisher page 49 citations

Abstract

Coronary velocity measurements have been carried out in anaesthetized, open-chest horses using a constant-temperature, hot-film anemometer system. L-shaped needle probes inserted by direct vessel puncture have been used to measure velocity profiles in the left common, left anterior descending (LAD), and left circumflex coronary arteries. The flow conditions were characterized by peak Reynolds numbers from approximately 200 to 1500 and values of the unsteadiness parameter from 3 to 10. These measurements indicate that in the left common coronary artery the profile is in general skewed towards the outer wall as would be expected for fully viscous flow in a curved tube. In the left anterior descending and left circumflex coronary arteries just distal to the bifurcation, the skewing was found in general to be away from the flow divider. However, in regions of the LAD and left circumflex 5-6 diameters downstream of the bifurcation, the peak systolic and diastolic profiles were indicative of a more fully developed, Poiseuille type flow with only slight skewing observed. The results of this study indicate that the flow in the coronary system, though in general laminar and disturbance free, is extremely varied in character and may exhibit large amplitude, low frequency flow oscillations. Furthermore, for these vessels which all lie on the surface of the myocardium, large systolic flows were observed to be present, even though the major portion of the volume flow was reserved for the diastolic period.

About this research paper

What this paper is about

Coronary velocity measurements have been carried out in anaesthetized, open-chest horses using a constant-temperature, hot-film anemometer system. L-shaped needle probes inserted by direct vessel puncture have been used to measure velocity profiles in the left common, left anterior descending (LAD), and left circumflex coronary arteries. The flow conditions were characterized by peak Reynolds numbers from approximately 200 to 1500 and values of the unsteadiness parameter from 3 to 10. These measurements indicate that in the left common coronary artery the profile is in general skewed towards the outer wall as would be expected for fully viscous flow in a curved tube. In the left anterior descending and left circumflex coronary arteries just distal to the bifurcation, the skewing was found in general to be away from the flow divider. However, in regions of the LAD and left circumflex 5-6 diameters downstream of the bifurcation, the peak systolic and diastolic profiles were indicative of a more fully developed, Poiseuille type flow with only slight skewing observed. The results of this study indicate that the flow in the coronary system, though in general laminar and disturbance free, is extremely varied in character and may exhibit large amplitude, low frequency flow oscillations. Furthermore, for these vessels which all lie on the surface of the myocardium, large systolic flows were observed to be present, even though the major portion of the volume flow was reserved for the diastolic period.

Why it matters

OpenAlex reports 49 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Coronary velocity measurements have been carried out in anaesthetized, open-chest horses using a constant-temperature, hot-film anemometer system. L-shaped needle probes inserted by direct vessel puncture have been used to measure velocity profiles in the left common, left anterior descending (LAD), and left circumflex coronary arteries. The flow conditions were characterized by peak Reynolds numbers from approximately 200 to 1500 and values of the unsteadiness parameter from 3 to 10. These measurements indicate that in the left common coronary artery the profile is in general skewed towards the outer wall as would be expected for fully viscous flow in a curved tube. In the left anterior descending and left circumflex coronary arteries just distal to the bifurcation, the skewing was found in general to be away from the flow divider. However, in regions of the LAD and left circumflex 5-6 diameters downstream of the bifurcation, the peak systolic and diastolic profiles were indicative of a more fully developed, Poiseuille type flow with only slight skewing observed. The results of this study indicate that the flow in the coronary system, though in general laminar and disturbance free, is extremely varied in character and may exhibit large amplitude, low frequency flow oscillations. Furthermore, for these vessels which all lie on the surface of the myocardium, large systolic flows were observed to be present, even though the major portion of the volume flow was reserved for the diastolic period.

Key concepts: Circumflex, Diastole, Laminar flow, Cardiology, Reynolds number, Coronary arteries, Medicine, Artery

Related papers

Back to paper searchBrowse research topicsOriginal source
Hot film coronary artery velocity measurements in horses — Research Paper | ScholarLens