1996Journal of Biomedical Materials ResearchRequires access

Surface adsorption and fibrinogen interactions with hirudin-thrombin complex

Rajashree Patel, Harvey A. Jacobs, Sung Wan Kim

Open publisher page 2 citations

Abstract

This study describes the protein interaction properties of hirudin-thrombin complex adsorbed onto a surface. Hirudin-thrombin complex, preadsorbed thrombin bound with hirudin, and thrombin were coated onto the surfaces of glass beads. The activity of the thrombin component adsorbed onto the surface, and hence the ability of hirudin to bind and inactivate thrombin, was determined by measuring the activity of thrombin to cleave fibrinogen to generate fibrin and to cleave a chromogenic substrate, S-2238. Pure thrombin adsorbed on the surface (without hirudin) retained its activity to cleave fibrinogen and cleave S-2238. Hirudin-thrombin complex adsorbed on the surface did not stimulate the activation of fibrinogen, nor did it cleave S-2238. Thrombin first adsorbed onto the surface was able to bind hirudin; this complex did not activate fibrinogen or the hydrolysis of S-2238. However, when hirudin was first adsorbed onto the surface followed by incubation with thrombin, the protein did not bind and neutralize thrombin, and therefore lost its biologic activity. Furthermore, all proteins and the hirudin-thrombin complex adsorbed onto the surface, as determined by protein binding assays. These results suggest that the hirudin-thrombin complex physically adsorbed onto the surface did not stimulate subsequent pathways in the coagulation system, mainly the activation of fibrinogen to fibrin. © 1996 John Wiley & Sons, Inc.

About this research paper

What this paper is about

This study describes the protein interaction properties of hirudin-thrombin complex adsorbed onto a surface. Hirudin-thrombin complex, preadsorbed thrombin bound with hirudin, and thrombin were coated onto the surfaces of glass beads. The activity of the thrombin component adsorbed onto the surface, and hence the ability of hirudin to bind and inactivate thrombin, was determined by measuring the activity of thrombin to cleave fibrinogen to generate fibrin and to cleave a chromogenic substrate, S-2238. Pure thrombin adsorbed on the surface (without hirudin) retained its activity to cleave fibrinogen and cleave S-2238. Hirudin-thrombin complex adsorbed on the surface did not stimulate the activation of fibrinogen, nor did it cleave S-2238. Thrombin first adsorbed onto the surface was able to bind hirudin; this complex did not activate fibrinogen or the hydrolysis of S-2238. However, when hirudin was first adsorbed onto the surface followed by incubation with thrombin, the protein did not bind and neutralize thrombin, and therefore lost its biologic activity. Furthermore, all proteins and the hirudin-thrombin complex adsorbed onto the surface, as determined by protein binding assays. These results suggest that the hirudin-thrombin complex physically adsorbed onto the surface did not stimulate subsequent pathways in the coagulation system, mainly the activation of fibrinogen to fibrin. © 1996 John Wiley & Sons, Inc.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study describes the protein interaction properties of hirudin-thrombin complex adsorbed onto a surface. Hirudin-thrombin complex, preadsorbed thrombin bound with hirudin, and thrombin were coated onto the surfaces of glass beads. The activity of the thrombin component adsorbed onto the surface, and hence the ability of hirudin to bind and inactivate thrombin, was determined by measuring the activity of thrombin to cleave fibrinogen to generate fibrin and to cleave a chromogenic substrate, S-2238. Pure thrombin adsorbed on the surface (without hirudin) retained its activity to cleave fibrinogen and cleave S-2238. Hirudin-thrombin complex adsorbed on the surface did not stimulate the activation of fibrinogen, nor did it cleave S-2238. Thrombin first adsorbed onto the surface was able to bind hirudin; this complex did not activate fibrinogen or the hydrolysis of S-2238. However, when hirudin was first adsorbed onto the surface followed by incubation with thrombin, the protein did not bind and neutralize thrombin, and therefore lost its biologic activity. Furthermore, all proteins and the hirudin-thrombin complex adsorbed onto the surface, as determined by protein binding assays. These results suggest that the hirudin-thrombin complex physically adsorbed onto the surface did not stimulate subsequent pathways in the coagulation system, mainly the activation of fibrinogen to fibrin. © 1996 John Wiley & Sons, Inc.

Key concepts: Hirudin, Thrombin, Cleave, Fibrinogen, Fibrin, Chemistry, Coagulation, Biophysics

Related papers

Back to paper searchBrowse research topicsOriginal source
Surface adsorption and fibrinogen interactions with hirudin-thrombin complex — Research Paper | ScholarLens