1997Acta Physiologica ScandinavicaRequires access

Distribution of pulmonary ventilation and perfusion measured simultaneously in awake goats

Morten Nissen Melsom, Jo Kramer‐Johansen, Torun Flatebø, Carsten Müller, Gunnar Nicolaysen

Open publisher page 56 citations

Abstract

Gravity has been regarded as the major determinant for local pulmonary perfusion and ventilation. Recent reports, describing major gravity independent heterogeneity in both variables, have questioned the importance of gravity. We asked to what extent ventilation and perfusion were related, and if they showed similar distributions along the vertical axis in the lung. We gave 99mTc-aerosols as tracers for ventilation and radioactive microspheres as blood flow tracers in five awake goats over 4 min. Ventilation and perfusion were determined in approximately 1.5 cm3 pieces of the lung. For both variables the vertical distribution could vary considerably from lung to lung, but within each lung the two distributions were similar. Both ventilation and perfusion were heterogeneously distributed (CV approximately 40% for both), they were highly correlated (r = 0.81) and the average 25-75-interpercentile interval for ventilation to perfusion ratio (0.84-1.13) was significantly less wide than for both ventilation (0.76-1.38) and perfusion (0.76-1.40). Some pieces were considerably overventilated while a few were correspondingly underventilated. This could indicate that perfusion is adjusted to ventilation in normoxic lungs with a low sensitivity to overventilation.

About this research paper

What this paper is about

Gravity has been regarded as the major determinant for local pulmonary perfusion and ventilation. Recent reports, describing major gravity independent heterogeneity in both variables, have questioned the importance of gravity. We asked to what extent ventilation and perfusion were related, and if they showed similar distributions along the vertical axis in the lung. We gave 99mTc-aerosols as tracers for ventilation and radioactive microspheres as blood flow tracers in five awake goats over 4 min. Ventilation and perfusion were determined in approximately 1.5 cm3 pieces of the lung. For both variables the vertical distribution could vary considerably from lung to lung, but within each lung the two distributions were similar. Both ventilation and perfusion were heterogeneously distributed (CV approximately 40% for both), they were highly correlated (r = 0.81) and the average 25-75-interpercentile interval for ventilation to perfusion ratio (0.84-1.13) was significantly less wide than for both ventilation (0.76-1.38) and perfusion (0.76-1.40). Some pieces were considerably overventilated while a few were correspondingly underventilated. This could indicate that perfusion is adjusted to ventilation in normoxic lungs with a low sensitivity to overventilation.

Why it matters

OpenAlex reports 56 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Gravity has been regarded as the major determinant for local pulmonary perfusion and ventilation. Recent reports, describing major gravity independent heterogeneity in both variables, have questioned the importance of gravity. We asked to what extent ventilation and perfusion were related, and if they showed similar distributions along the vertical axis in the lung. We gave 99mTc-aerosols as tracers for ventilation and radioactive microspheres as blood flow tracers in five awake goats over 4 min. Ventilation and perfusion were determined in approximately 1.5 cm3 pieces of the lung. For both variables the vertical distribution could vary considerably from lung to lung, but within each lung the two distributions were similar. Both ventilation and perfusion were heterogeneously distributed (CV approximately 40% for both), they were highly correlated (r = 0.81) and the average 25-75-interpercentile interval for ventilation to perfusion ratio (0.84-1.13) was significantly less wide than for both ventilation (0.76-1.38) and perfusion (0.76-1.40). Some pieces were considerably overventilated while a few were correspondingly underventilated. This could indicate that perfusion is adjusted to ventilation in normoxic lungs with a low sensitivity to overventilation.

Key concepts: Ventilation (architecture), Perfusion, Ventilation perfusion mismatch, Lung, Anesthesia, Medicine, Distribution (mathematics), Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Distribution of pulmonary ventilation and perfusion measured simultaneously in awake goats — Research Paper | ScholarLens