1993European Heart JournalRequires access

Effect of atrial fibrillation on pulmonary venous flow patterns: transoesophageal pulsed Doppler echocardiographic study

Wen-Jun Ren, Pieralberto Visentin, Gian Luigi Nicolosi, F. Antonini Canterin, V. Dall'Aglio, Chiara Lestuzzi, Renata Mimo, Daniela Pavan, Lina Sparacino, Eugenio Cervesato, Davide Zanuttini

Open publisher page 31 citations

Abstract

The effect of atrial fibrillation on pulmonary venous flow patterns is still not well known. Twenty-four patients in atrial fibrillation and 21 patients in sinus rhythm were studied by transoesophageal echocardiography. In ninety-five percent (20/21) of sinus rhythm patients, the early systolic wave due to atrial relaxation or reverse wave due to atrial contraction could be distinguished on pulsed Doppler tracings by transoesophageal echocardiography. However, there was no early systolic wave and/or reverse at the end of diastole in any atrial fibrillation patients. In atrial fibrillation patients without mitral regurgitation (n = 14), the onset of systolic flow was delayed (165 +/- 38 vs 50 +/- 46 ms, P < 0.05), and systolic peak velocities, time-velocity integrals and systolic fractions were reduced (31 +/- 13 vs 54 +/- 17 cm.s-1, P < 0.05; 5 +/- 2 vs 13 +/- 6 cm, P < 0.05 and 36 +/- 8 vs 61 +/- 15%, P < 0.05, respectively) as compared to those in sinus rhythm. Significant mitral regurgitation (n = 10) reduced systolic velocity parameters considerably in atrial fibrillation patients but the diastolic flow parameters were not significantly different between sinus rhythm and atrial fibrillation patients. Stepwise multiple regression analysis identified atrial fibrillation as an important independent predictor for changes in systolic flow parameters. The R-R interval is also an important factor for diastolic flow parameters. Thus, the present study demonstrates that atrial fibrillation significantly modifies pulmonary venous flow pattern and is an important factor for systolic flow parameters. Significant mitral regurgitation can further modify systolic flow pattern in atrial fibrillation patients.

About this research paper

What this paper is about

The effect of atrial fibrillation on pulmonary venous flow patterns is still not well known. Twenty-four patients in atrial fibrillation and 21 patients in sinus rhythm were studied by transoesophageal echocardiography. In ninety-five percent (20/21) of sinus rhythm patients, the early systolic wave due to atrial relaxation or reverse wave due to atrial contraction could be distinguished on pulsed Doppler tracings by transoesophageal echocardiography. However, there was no early systolic wave and/or reverse at the end of diastole in any atrial fibrillation patients. In atrial fibrillation patients without mitral regurgitation (n = 14), the onset of systolic flow was delayed (165 +/- 38 vs 50 +/- 46 ms, P < 0.05), and systolic peak velocities, time-velocity integrals and systolic fractions were reduced (31 +/- 13 vs 54 +/- 17 cm.s-1, P < 0.05; 5 +/- 2 vs 13 +/- 6 cm, P < 0.05 and 36 +/- 8 vs 61 +/- 15%, P < 0.05, respectively) as compared to those in sinus rhythm. Significant mitral regurgitation (n = 10) reduced systolic velocity parameters considerably in atrial fibrillation patients but the diastolic flow parameters were not significantly different between sinus rhythm and atrial fibrillation patients. Stepwise multiple regression analysis identified atrial fibrillation as an important independent predictor for changes in systolic flow parameters. The R-R interval is also an important factor for diastolic flow parameters. Thus, the present study demonstrates that atrial fibrillation significantly modifies pulmonary venous flow pattern and is an important factor for systolic flow parameters. Significant mitral regurgitation can further modify systolic flow pattern in atrial fibrillation patients.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effect of atrial fibrillation on pulmonary venous flow patterns is still not well known. Twenty-four patients in atrial fibrillation and 21 patients in sinus rhythm were studied by transoesophageal echocardiography. In ninety-five percent (20/21) of sinus rhythm patients, the early systolic wave due to atrial relaxation or reverse wave due to atrial contraction could be distinguished on pulsed Doppler tracings by transoesophageal echocardiography. However, there was no early systolic wave and/or reverse at the end of diastole in any atrial fibrillation patients. In atrial fibrillation patients without mitral regurgitation (n = 14), the onset of systolic flow was delayed (165 +/- 38 vs 50 +/- 46 ms, P < 0.05), and systolic peak velocities, time-velocity integrals and systolic fractions were reduced (31 +/- 13 vs 54 +/- 17 cm.s-1, P < 0.05; 5 +/- 2 vs 13 +/- 6 cm, P < 0.05 and 36 +/- 8 vs 61 +/- 15%, P < 0.05, respectively) as compared to those in sinus rhythm. Significant mitral regurgitation (n = 10) reduced systolic velocity parameters considerably in atrial fibrillation patients but the diastolic flow parameters were not significantly different between sinus rhythm and atrial fibrillation patients. Stepwise multiple regression analysis identified atrial fibrillation as an important independent predictor for changes in systolic flow parameters. The R-R interval is also an important factor for diastolic flow parameters. Thus, the present study demonstrates that atrial fibrillation significantly modifies pulmonary venous flow pattern and is an important factor for systolic flow parameters. Significant mitral regurgitation can further modify systolic flow pattern in atrial fibrillation patients.

Key concepts: Medicine, Cardiology, Atrial fibrillation, Internal medicine, Sinus rhythm, Diastole, P wave, Mitral regurgitation

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of atrial fibrillation on pulmonary venous flow patterns: transoesophageal pulsed Doppler echocardiographic study — Research Paper | ScholarLens