2012American Journal of AudiologyOpen access

Sequential Bilateral Cochlear Implantation: Speech Perception and Localization Pre- and Post-Second Cochlear Implantation

Camille C. Dunn, Richard S. Tyler, Shelley Witt, Haihong Ji, Bruce J. Gantz

Open full text 25 citations

Abstract

PURPOSE: In this study, the authors sought to compare speech perception and localization in subjects who wear 1 cochlear implant (unilateral CI) or 1 cochlear implant and hearing aid (CI+HA) and then receive a second cochlear implant (bilateral CI), and to evaluate the importance of the duration between implant surgeries and duration of deafness. METHOD: Nine subjects were tested on speech perception in quiet, and 13 subjects were tested on speech perception and localization in noise using an array of 8 loudspeakers. All subjects were tested with unilateral CI prior to bilateral implantation and then again with bilateral CI after at least 3 months of bilateral experience. RESULTS: No significant difference was found between bilateral CI and unilateral CI on averaged speech perception in quiet performance. A significant benefit was found for bilateral CI on averaged speech perception in noise and on localization. Nonsignificant correlations were found for duration between surgeries, duration of deafness, and duration of bilateral use. CONCLUSIONS: Improvements for speech perception and localization played in background noise were indicated for most subjects after they received their 2nd implant. The correlations should be reassessed with a larger number of subjects to appropriately evaluate the effects of duration between surgeries, duration of deafness, and duration of bilateral use.

About this research paper

What this paper is about

PURPOSE: In this study, the authors sought to compare speech perception and localization in subjects who wear 1 cochlear implant (unilateral CI) or 1 cochlear implant and hearing aid (CI+HA) and then receive a second cochlear implant (bilateral CI), and to evaluate the importance of the duration between implant surgeries and duration of deafness. METHOD: Nine subjects were tested on speech perception in quiet, and 13 subjects were tested on speech perception and localization in noise using an array of 8 loudspeakers. All subjects were tested with unilateral CI prior to bilateral implantation and then again with bilateral CI after at least 3 months of bilateral experience. RESULTS: No significant difference was found between bilateral CI and unilateral CI on averaged speech perception in quiet performance. A significant benefit was found for bilateral CI on averaged speech perception in noise and on localization. Nonsignificant correlations were found for duration between surgeries, duration of deafness, and duration of bilateral use. CONCLUSIONS: Improvements for speech perception and localization played in background noise were indicated for most subjects after they received their 2nd implant. The correlations should be reassessed with a larger number of subjects to appropriately evaluate the effects of duration between surgeries, duration of deafness, and duration of bilateral use.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: In this study, the authors sought to compare speech perception and localization in subjects who wear 1 cochlear implant (unilateral CI) or 1 cochlear implant and hearing aid (CI+HA) and then receive a second cochlear implant (bilateral CI), and to evaluate the importance of the duration between implant surgeries and duration of deafness. METHOD: Nine subjects were tested on speech perception in quiet, and 13 subjects were tested on speech perception and localization in noise using an array of 8 loudspeakers. All subjects were tested with unilateral CI prior to bilateral implantation and then again with bilateral CI after at least 3 months of bilateral experience. RESULTS: No significant difference was found between bilateral CI and unilateral CI on averaged speech perception in quiet performance. A significant benefit was found for bilateral CI on averaged speech perception in noise and on localization. Nonsignificant correlations were found for duration between surgeries, duration of deafness, and duration of bilateral use. CONCLUSIONS: Improvements for speech perception and localization played in background noise were indicated for most subjects after they received their 2nd implant. The correlations should be reassessed with a larger number of subjects to appropriately evaluate the effects of duration between surgeries, duration of deafness, and duration of bilateral use.

Key concepts: Audiology, Cochlear implant, Speech perception, QUIET, Duration (music), Medicine, Implant, Cochlear implantation

Related papers

Back to paper searchBrowse research topicsOriginal source
Sequential Bilateral Cochlear Implantation: Speech Perception and Localization Pre- and Post-Second Cochlear Implantation — Research Paper | ScholarLens