1993Acta OphthalmologicaRequires access

Refractive results after phacoemulsification and ECCE

Mikael Dam‐Johansen, Thomas Olsen

Open publisher page 24 citations

Abstract

The refractive results were evaluated in 79 patients undergoing cataract extraction by phacoemulsification using a 6-7 mm tunnel incision, and compared with a group of 77 patients undergoing planned extracapsular cataract extraction (ECCE) by the same surgeon. A mean increase in the keratometric cylinder of 0.05D and 0.52D was found in the phacoemulsification and the extracapsular cataract extraction group, respectively. This was significantly different from zero for the extracapsular cataract extraction group (p < 0.05) but not for the phacoemulsification group (p > 0.05). By vector analysis, the mean surgically induced astigmatism was 0.91D and 1.36D in the phacoemulsification and the extracapsular cataract extraction group, respectively (p < 0.01). The IOL power prediction error (spectacle plane) was found to be 0.17D (+/- 0.69 SD) in the phacoemulsification group and 0.02 D (+/- 0.79 SD) in the extracapsular cataract extraction group, respectively. We conclude that phacoemulsification improves the surgical control of the refractive outcome of cataract surgery.

About this research paper

What this paper is about

The refractive results were evaluated in 79 patients undergoing cataract extraction by phacoemulsification using a 6-7 mm tunnel incision, and compared with a group of 77 patients undergoing planned extracapsular cataract extraction (ECCE) by the same surgeon. A mean increase in the keratometric cylinder of 0.05D and 0.52D was found in the phacoemulsification and the extracapsular cataract extraction group, respectively. This was significantly different from zero for the extracapsular cataract extraction group (p < 0.05) but not for the phacoemulsification group (p > 0.05). By vector analysis, the mean surgically induced astigmatism was 0.91D and 1.36D in the phacoemulsification and the extracapsular cataract extraction group, respectively (p < 0.01). The IOL power prediction error (spectacle plane) was found to be 0.17D (+/- 0.69 SD) in the phacoemulsification group and 0.02 D (+/- 0.79 SD) in the extracapsular cataract extraction group, respectively. We conclude that phacoemulsification improves the surgical control of the refractive outcome of cataract surgery.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The refractive results were evaluated in 79 patients undergoing cataract extraction by phacoemulsification using a 6-7 mm tunnel incision, and compared with a group of 77 patients undergoing planned extracapsular cataract extraction (ECCE) by the same surgeon. A mean increase in the keratometric cylinder of 0.05D and 0.52D was found in the phacoemulsification and the extracapsular cataract extraction group, respectively. This was significantly different from zero for the extracapsular cataract extraction group (p < 0.05) but not for the phacoemulsification group (p > 0.05). By vector analysis, the mean surgically induced astigmatism was 0.91D and 1.36D in the phacoemulsification and the extracapsular cataract extraction group, respectively (p < 0.01). The IOL power prediction error (spectacle plane) was found to be 0.17D (+/- 0.69 SD) in the phacoemulsification group and 0.02 D (+/- 0.79 SD) in the extracapsular cataract extraction group, respectively. We conclude that phacoemulsification improves the surgical control of the refractive outcome of cataract surgery.

Key concepts: Phacoemulsification, Medicine, Cataract extraction, Ophthalmology, Astigmatism, Surgery, Visual acuity, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Refractive results after phacoemulsification and ECCE — Research Paper | ScholarLens