Effect of photo-activated disinfection on bond strength of three different root canal sealers
Evren Ok, Hüseyin Ertaş, Gökhan Saygılı, Tuba Gök
Abstract
Open-access reader
Evren Ok, Hüseyin Ertaş, Gökhan Saygılı, Tuba Gök
Abstract
Open-access reader
INTRODUCTION: The aim of this in vitro study was to evaluate the bond strength of Photo-Activated Disinfection (PAD) system to dentin with different root canal sealers by using a push-out test design. MATERIALS AND METHODS: A total of 30 extracted mandibular premolar teeth with single and straight roots were used. The crowns were removed and the root canals were prepared by using ProTaper rotary files. The smear layer was removed and the roots were randomly divided into two groups (n = 15) according to the use of PAD system as the final disinfecting agent. Each group was then divided into 6 (n = 5) subgroups and obturated with gutta-percha and 3 different root canal sealers. The groups were Group 1: Sodium hypochlorite (NaOCl) + ethylenediaminetetraacetic acid (EDTA)-AH Plus sealer; Group 2: NaOCl + EDTA + PAD-AH Plus; Group 3: NaOCl + EDTA-Sealapex; Group 4: NaOCl + EDTA + PAD-Sealapex; Group 5: NaOCl + EDTA-mineral trioxide aggregate (MTA)-Fiallapex; and Group 6: NaOCl + EDTA + PAD-MTA-Fillapex. 1-mm thickness horizontal sections (n: 5 × 4 = 20) were sliced for the push-out bond strength measurement. RESULTS: Group 3 and 4 showed significantly lower bond strengths compared with all the other groups (P < 0.05). No statistically significant difference was found among Groups 1, 2 and 5, but there was statistically significant difference between Group 5 and 6 (P < 0.05). CONCLUSION: This in vitro study indicated that the PAD system adversely affected the bond strength of the MTA Fillapex root canal sealer.
OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
INTRODUCTION: The aim of this in vitro study was to evaluate the bond strength of Photo-Activated Disinfection (PAD) system to dentin with different root canal sealers by using a push-out test design. MATERIALS AND METHODS: A total of 30 extracted mandibular premolar teeth with single and straight roots were used. The crowns were removed and the root canals were prepared by using ProTaper rotary files. The smear layer was removed and the roots were randomly divided into two groups (n = 15) according to the use of PAD system as the final disinfecting agent. Each group was then divided into 6 (n = 5) subgroups and obturated with gutta-percha and 3 different root canal sealers. The groups were Group 1: Sodium hypochlorite (NaOCl) + ethylenediaminetetraacetic acid (EDTA)-AH Plus sealer; Group 2: NaOCl + EDTA + PAD-AH Plus; Group 3: NaOCl + EDTA-Sealapex; Group 4: NaOCl + EDTA + PAD-Sealapex; Group 5: NaOCl + EDTA-mineral trioxide aggregate (MTA)-Fiallapex; and Group 6: NaOCl + EDTA + PAD-MTA-Fillapex. 1-mm thickness horizontal sections (n: 5 × 4 = 20) were sliced for the push-out bond strength measurement. RESULTS: Group 3 and 4 showed significantly lower bond strengths compared with all the other groups (P < 0.05). No statistically significant difference was found among Groups 1, 2 and 5, but there was statistically significant difference between Group 5 and 6 (P < 0.05). CONCLUSION: This in vitro study indicated that the PAD system adversely affected the bond strength of the MTA Fillapex root canal sealer.
Key concepts: Sodium hypochlorite, Bond strength, Mineral trioxide aggregate, Root canal, Smear layer, Dentistry, Dentin, Chemistry