A Comparison of Air-Blast and Flow-Blurring Injectors Using Phase Doppler Particle Analyzer Technique

Benjamin M. Simmons, Heena Panchasara, Ajay K. Agrawal

Open publisher page 46 citations

Abstract

Recent research on biofuels for power generation has typically focused on biodiesel because the biodiesel feedstrock, e.g., vegetable oil, poses significant combustion problems related to poor atomization. Existing injectors cannot effectively atomize high viscosity fuels such as vegetable oil. However, a new, novel flow-blurring (FB) injector concept has shown promise in overcoming the atomization problems. In this study, a FB injector is compared to a commercial air-blast (AB) injector operated with water at ambient conditions of temperature and pressure. Laser sheet visualization and Phase Doppler Particle Analyzer (PDPA) systems are used to obtain the spray characteristics for a range of air to liquid (ALR) ratios. Results show significant difference in distributions of Sauter Mean Diameters (SMDs), and mean and root-mean square axial velocity for the two injectors operated at a fixed ALR. In comparison to the AB injector, the FB injector produced spray with smaller SMDs, a smaller SMD range over the spray volume, higher RMS and mean axial velocities in the center region, and a compact spray with spray angle nearly independent of ALR. Results show that the FB injector is an effective way of atomizing liquids at relatively low ALRs compared to a traditional AB injector, without the additional pressure drop penalty.

About this research paper

What this paper is about

Recent research on biofuels for power generation has typically focused on biodiesel because the biodiesel feedstrock, e.g., vegetable oil, poses significant combustion problems related to poor atomization. Existing injectors cannot effectively atomize high viscosity fuels such as vegetable oil. However, a new, novel flow-blurring (FB) injector concept has shown promise in overcoming the atomization problems. In this study, a FB injector is compared to a commercial air-blast (AB) injector operated with water at ambient conditions of temperature and pressure. Laser sheet visualization and Phase Doppler Particle Analyzer (PDPA) systems are used to obtain the spray characteristics for a range of air to liquid (ALR) ratios. Results show significant difference in distributions of Sauter Mean Diameters (SMDs), and mean and root-mean square axial velocity for the two injectors operated at a fixed ALR. In comparison to the AB injector, the FB injector produced spray with smaller SMDs, a smaller SMD range over the spray volume, higher RMS and mean axial velocities in the center region, and a compact spray with spray angle nearly independent of ALR. Results show that the FB injector is an effective way of atomizing liquids at relatively low ALRs compared to a traditional AB injector, without the additional pressure drop penalty.

Why it matters

OpenAlex reports 46 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Recent research on biofuels for power generation has typically focused on biodiesel because the biodiesel feedstrock, e.g., vegetable oil, poses significant combustion problems related to poor atomization. Existing injectors cannot effectively atomize high viscosity fuels such as vegetable oil. However, a new, novel flow-blurring (FB) injector concept has shown promise in overcoming the atomization problems. In this study, a FB injector is compared to a commercial air-blast (AB) injector operated with water at ambient conditions of temperature and pressure. Laser sheet visualization and Phase Doppler Particle Analyzer (PDPA) systems are used to obtain the spray characteristics for a range of air to liquid (ALR) ratios. Results show significant difference in distributions of Sauter Mean Diameters (SMDs), and mean and root-mean square axial velocity for the two injectors operated at a fixed ALR. In comparison to the AB injector, the FB injector produced spray with smaller SMDs, a smaller SMD range over the spray volume, higher RMS and mean axial velocities in the center region, and a compact spray with spray angle nearly independent of ALR. Results show that the FB injector is an effective way of atomizing liquids at relatively low ALRs compared to a traditional AB injector, without the additional pressure drop penalty.

Key concepts: Injector, Sauter mean diameter, Spray characteristics, Ignition system, Combustion, Materials science, Range (aeronautics), Combustion chamber

Related papers

Back to paper searchBrowse research topicsOriginal source
A Comparison of Air-Blast and Flow-Blurring Injectors Using Phase Doppler Particle Analyzer Technique — Research Paper | ScholarLens