2002•International Journal of Molecular MedicineRequires access

An HPLC method for the measurement of 5-fluorouracil in human plasma with a low detection limit and a high extraction yield

M A Nassim, Farshad H. Shirazi, C. Cripps, S Veerasinghan, M. Molepo, Mihail Obrocea, Diedre Redmond, Susan E. Bates, Diane Fry, David J. Stewart, Rakesh Goel

Open publisher page 27 citations

Abstract

High performance liquid chromatographic (HPLC) techniques for the quantification of 5-fluorouracil (5-FU) in human plasma have been reported in the literature, however, a low limit of detection was generally found to result in a comparatively low extraction yield. We have developed a simple, rapid and sensitive HPLC method for the measurement of 5-FU in plasma which provides both a low limit of quantification and a high extraction yield. This method involves the solid phase extraction of 5-FU from a 500 microl plasma sample. The extract is then injected into an HPLC system equipped with a C18 (mu)Bondapak column, and a UV detector set at 260 nm. Ethyl acetate and potassium dihydrogen phosphate are used for the solid phase extraction and the HPLC mobile phase, respectively. This method provides in a good baseline, a sharp and symmetrical peak for 5-FU, and a high resolution between 5-FU and the internal standard. The retention time of 5-FU using this method is 4.7 min with a limit of detection of 5 ng/ml, and an extraction yield of 96.2+/-0.5% (SE). The next injection is possible in 11 min, and the coefficients of variation are 4.2-8.9% for interday precision, and 5.2-10.6% for day-to-day reproducibility. An HPLC method has been developed that has a low limit of detection and a high extraction yield. This technique was successfully applied in a clinical pharmacokinetic study of 5-FU.

About this research paper

What this paper is about

High performance liquid chromatographic (HPLC) techniques for the quantification of 5-fluorouracil (5-FU) in human plasma have been reported in the literature, however, a low limit of detection was generally found to result in a comparatively low extraction yield. We have developed a simple, rapid and sensitive HPLC method for the measurement of 5-FU in plasma which provides both a low limit of quantification and a high extraction yield. This method involves the solid phase extraction of 5-FU from a 500 microl plasma sample. The extract is then injected into an HPLC system equipped with a C18 (mu)Bondapak column, and a UV detector set at 260 nm. Ethyl acetate and potassium dihydrogen phosphate are used for the solid phase extraction and the HPLC mobile phase, respectively. This method provides in a good baseline, a sharp and symmetrical peak for 5-FU, and a high resolution between 5-FU and the internal standard. The retention time of 5-FU using this method is 4.7 min with a limit of detection of 5 ng/ml, and an extraction yield of 96.2+/-0.5% (SE). The next injection is possible in 11 min, and the coefficients of variation are 4.2-8.9% for interday precision, and 5.2-10.6% for day-to-day reproducibility. An HPLC method has been developed that has a low limit of detection and a high extraction yield. This technique was successfully applied in a clinical pharmacokinetic study of 5-FU.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High performance liquid chromatographic (HPLC) techniques for the quantification of 5-fluorouracil (5-FU) in human plasma have been reported in the literature, however, a low limit of detection was generally found to result in a comparatively low extraction yield. We have developed a simple, rapid and sensitive HPLC method for the measurement of 5-FU in plasma which provides both a low limit of quantification and a high extraction yield. This method involves the solid phase extraction of 5-FU from a 500 microl plasma sample. The extract is then injected into an HPLC system equipped with a C18 (mu)Bondapak column, and a UV detector set at 260 nm. Ethyl acetate and potassium dihydrogen phosphate are used for the solid phase extraction and the HPLC mobile phase, respectively. This method provides in a good baseline, a sharp and symmetrical peak for 5-FU, and a high resolution between 5-FU and the internal standard. The retention time of 5-FU using this method is 4.7 min with a limit of detection of 5 ng/ml, and an extraction yield of 96.2+/-0.5% (SE). The next injection is possible in 11 min, and the coefficients of variation are 4.2-8.9% for interday precision, and 5.2-10.6% for day-to-day reproducibility. An HPLC method has been developed that has a low limit of detection and a high extraction yield. This technique was successfully applied in a clinical pharmacokinetic study of 5-FU.

Key concepts: Detection limit, Chromatography, High-performance liquid chromatography, Extraction (chemistry), Yield (engineering), Reproducibility, Solid phase extraction, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
An HPLC method for the measurement of 5-fluorouracil in human plasma with a low detection limit and a high extraction yield — Research Paper | ScholarLens