2013•NanotechnologyRequires access

A compact torsional reference device for easy, accurate and traceable AFM piconewton calibration

José F. Portolés, Peter J. Cumpson

Open publisher page 10 citations

Abstract

The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.

About this research paper

What this paper is about

The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.

Key concepts: Traceability, Calibration, Cantilever, Materials science, Repeatability, Kilogram, Atomic force microscopy, Ampere

Related papers

Back to paper searchBrowse research topicsOriginal source
A compact torsional reference device for easy, accurate and traceable AFM piconewton calibration — Research Paper | ScholarLens