The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.
Key concepts: Traceability, Calibration, Cantilever, Materials science, Repeatability, Kilogram, Atomic force microscopy, Ampere