1978Bulletin of the Chemical Society of JapanRequires access

Determination of Micro Amounts of Polythionates. X. Spectrophotometric Determination of Micro Amounts of Pentathionate in Mixtures with Thiosulfate and Sulfite by Means of Its Sulfitolysis

Tomozo Koh, Kazuo Taniguchi, Iwaji Iwasaki

Open publisher page 14 citations

Abstract

Abstract An accurate method has been proposed for the determination of pentathionate in mixtures with thiosulfate and sulfite. The method is based on the formation of thiosulfate equivalent to the pentathionate, and the spectrophotometric determination of excess iodine for the reaction with the thiosulfate formed. The conditions for pentathionate to be quantitatively converted into thiosulfate were established by varying pH, reaction time, and amounts of sulfite. The method can be successfully applied to the determination of pentathionate, thiosulfate, and sulfite when they are mixed in various ratios, giving a relative standard deviation of 0.82% at the 0.5 μmol level of pentathionate in a 10.0 cm3 sample solution in the presence of 0.5 μmol of thiosulfate and 0.25 μmol of sulfite.

About this research paper

What this paper is about

Abstract An accurate method has been proposed for the determination of pentathionate in mixtures with thiosulfate and sulfite. The method is based on the formation of thiosulfate equivalent to the pentathionate, and the spectrophotometric determination of excess iodine for the reaction with the thiosulfate formed. The conditions for pentathionate to be quantitatively converted into thiosulfate were established by varying pH, reaction time, and amounts of sulfite. The method can be successfully applied to the determination of pentathionate, thiosulfate, and sulfite when they are mixed in various ratios, giving a relative standard deviation of 0.82% at the 0.5 μmol level of pentathionate in a 10.0 cm3 sample solution in the presence of 0.5 μmol of thiosulfate and 0.25 μmol of sulfite.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract An accurate method has been proposed for the determination of pentathionate in mixtures with thiosulfate and sulfite. The method is based on the formation of thiosulfate equivalent to the pentathionate, and the spectrophotometric determination of excess iodine for the reaction with the thiosulfate formed. The conditions for pentathionate to be quantitatively converted into thiosulfate were established by varying pH, reaction time, and amounts of sulfite. The method can be successfully applied to the determination of pentathionate, thiosulfate, and sulfite when they are mixed in various ratios, giving a relative standard deviation of 0.82% at the 0.5 μmol level of pentathionate in a 10.0 cm3 sample solution in the presence of 0.5 μmol of thiosulfate and 0.25 μmol of sulfite.

Key concepts: Thiosulfate, Sulfite, Chemistry, Relative standard deviation, Sodium thiosulfate, Inorganic chemistry, Tetrathionate, Sulfur

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Micro Amounts of Polythionates. X. Spectrophotometric Determination of Micro Amounts of Pentathionate in Mixtures with Thiosulfate and Sulfite by Means of Its Sulfitolysis — Research Paper | ScholarLens